Suspected acquired hypocobalaminaemic encephalopathy in a cat: resolution of encephalopathic signs and MRI lesions subsequent to cobalamin supplementation.

Simpson Katherine, Battersby Ian, Lowrie Mark

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: PRESENTING SIGNS AND INITIAL INVESTIGATIONS: An 8-year-old female spayed British shorthair cat was presented with a history of waxing and waning neurological signs. Neuroanatomical localisation was consistent with a diffuse forebrain disease. Blood ammonia concentration was increased. Abdominal ultrasonography and a bile acid stimulation test were normal. Magnetic resonance imaging (MRI) revealed hyperintense, bilaterally symmetrical, diffuse lesions on T2-weighted sequences, predominantly, but not exclusively, affecting the grey matter. Serum cobalamin (vitamin B12) concentration was low. Hypocobalaminaemia resulting in a urea cycle abnormality was considered a likely cause of the hyperammonaemia.

TREATMENT: Daily cobalamin injections resulted in a rapid clinical improvement. Eight weeks into treatment neurological examination was unremarkable and there was complete resolution of the MRI lesions.

CLINICAL

IMPORTANCE

This is the first reported case of acquired feline hypocobalaminaemia resulting in an encephalopathy. Additionally, this case is unique in describing reversible brain MRI abnormalities in a cobalamin-deficient companion animal.

Для цитирования: Simpson Katherine, Battersby Ian, Lowrie Mark. Suspected acquired hypocobalaminaemic encephalopathy in a cat: resolution of encephalopathic signs and MRI lesions subsequent to cobalamin supplementation.. Journal of feline medicine and surgery. 2012. DOI: 10.1177/1098612x12439358.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.