MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinph.2015.06.032

Медицинская библиотека · Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2015

Ultrasound and electrophysiologic findings in patients with Guillain-Barré syndrome at disease onset and over a period of six months.

Grimm Alexander, Décard Bernhard F, Schramm Axel, Pröbstel Anne-Katrin, Rasenack Maria, Axer Hubertus, Fuhr Peter

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate cross-sectional areas (CSAs) of several peripheral nerves including the vagus nerve and the diameter of spinal nerves as measured by nerve ultrasound (NUS) and nerve conduction studies (NCS) in Guillain-Barré syndrome (GBS) patients over at least six months compared to healthy controls.

METHODS

NUS and/or NCS of several nerves, the vagus nerve, and the 5th/6th cervical spinal nerves were performed in patients with GBS at days 2-3 after symptom onset, at days 10-14 after immunoglobulin therapy and after six months compared to healthy controls.

RESULTS

27 GBS-patients and 31 controls were included. Using NUS significant enlargement was found in all measured nerves (P<0.001), except the sural nerve (P=0.086) compared to the controls at onset. The vagus (median 3.0 mm(2) vs. 2.0 mm(2), P<0.0001) and the cervical spinal nerves were significantly enlarged (median 3.5/4.0 mm vs. 2.6/3.2 mm, p<0.0001), the vagus most obviously in patients with autonomic dysregulation (AD, 4.0 mm(2)). Six months later, NCS showed persisting pathology in CMAP-amplitudes with amelioration of F-wave pathology. NUS showed restitution in the spinal nerves (median 2.6/3.2 mm) and the vagus (median 2.0 mm(2)) in all patients excluding the vagus in those with persistent AD (median 4.0 mm(2)). The peripheral nerves did not change significantly (P>0.05).

CONCLUSION

Ultrasonographic detection of cervical spinal nerve enlargement supports the diagnosis of GBS in the early phase. Its regression may be a good parameter for the clinical restitution over time. Vagus enlargement may be a risk marker for development of AD.

SIGNIFICANCE: Ultrasound is a reliable diagnostic follow-up tool in early GBS.

Для цитирования: Grimm Alexander, Décard Bernhard F, Schramm Axel, Pröbstel Anne-Katrin, Rasenack Maria, Axer Hubertus, Fuhr Peter. Ultrasound and electrophysiologic findings in patients with Guillain-Barré syndrome at disease onset and over a period of six months.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2015. DOI: 10.1016/j.clinph.2015.06.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.