MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ehf2.12313

Медицинская библиотека · ESC heart failure · 2018

Haemodynamic effects of percutaneous mitral valve edge-to-edge repair in patients with end-stage heart failure awaiting heart transplantation.

Geis Nicolas A, Pleger Sven T, Bekeredjian Raffi, Chorianopoulos Emmanuel, Kreusser Michael M, Frankenstein Lutz, Ruhparwar Arjang, Katus Hugo A, Raake Philip W J

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Functional mitral regurgitation is complicating end-stage heart failure and potential heart transplantation by increasing pulmonary artery pressures. The aim of the present study was to investigate feasibility and haemodynamic effects of percutaneous mitral valve edge-to-edge repair using the MitraClip™ device in patients with end-stage heart failure awaiting heart transplantation.

METHODS AND

RESULTS

In this retrospective study, we identified nine patients suffering from end-stage heart failure listed for heart transplantation in whom moderate-severe or severe functional mitral regurgitation was recognized and treated with percutaneous mitral valve edge-to-edge repair. Twenty-two patients listed for heart transplantation and presenting with moderate-severe or severe functional mitral regurgitation treated in the pre-MitraClip™ era served as controls. Patients were analysed at two separate time points: MitraClip™ group: pre-procedure and post-procedure (follow-up: 215 ± 53 days) and control group: study entry with recognition of moderate-severe or severe functional mitral regurgitation (follow-up: 197 ± 47 days). Percutaneous mitral valve edge-to-edge repair with the MitraClip™ was feasible and safe in our high-risk end-stage heart failure population. The intervention resulted in significant reduction of mitral regurgitation (grade 3.0 [0.5] to 1.5 [0.5]; P = 0.009), left atrial diameter (51 mm [16] to 49 mm [4]; follow-up MitraClip™ vs. control group P = 0.0497), pulmonary artery pressures (sPA 50 mmHg [15] to 45 mmHg [10]; P = 0.02; mPA 34 mmHg [8] to 30 mmHg [10]; P = 0.02), and New York Heart Association class (3.5 [1.0] to 3.0 [0.5]; P = 0.01) and improved mixed-venous oxygen saturation (57% [11] to 55% [7]; follow-up MitraClip™ vs. control group P = 0.02). No changes in the control group were observed.

CONCLUSIONS

MitraClip™ implantation as 'bridge-to-transplant' strategy in patients with end-stage heart failure and severe functional mitral regurgitation awaiting heart transplantation is feasible and appears to result in favourable haemodynamic effects.

Для цитирования: Geis Nicolas A, Pleger Sven T, Bekeredjian Raffi, Chorianopoulos Emmanuel, Kreusser Michael M, Frankenstein Lutz, Ruhparwar Arjang, Katus Hugo A, Raake Philip W J. Haemodynamic effects of percutaneous mitral valve edge-to-edge repair in patients with end-stage heart failure awaiting heart transplantation.. ESC heart failure. 2018. DOI: 10.1002/ehf2.12313.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.