Robotic mitral valve operations by experienced surgeons are cost-neutral and durable at 1 year.

Coyan Garrett, Wei Lawrence M, Althouse Andrew, Roberts Harold G, Schauble Drew, Murashita Takashi, Cook Chris C, Rankin J Scott, Badhwar Vinay

Сравнительное исследованиеОценочное исследованиеСтатьяVideo-Audio MediaПеревод пока не подготовлен

Аннотация

BACKGROUND

Robotic mitral valve surgery has potential advantages in patient satisfaction and 30-day outcome. Cost concerns and repair durability limit wider adoption of robotic technology. This study examined detailed cost differences between robotic and sternotomy techniques in relation to outcomes and durability following robotic mitral program initiation.

METHODS

Between April 2013 and October 2015, 30-day and 1-year outcomes of 328 consecutive patients undergoing robotic or sternotomy mitral valve repair or replacement by experienced surgeons were examined. Multivariable logistic regression informed propensity matching to derive a cohort of 182 patients. Echocardiographic follow-up was completed at 1 year in all robotic patients. Detailed activity-based cost accounting was applied to include direct, semidirect, and indirect costs with special respect to robotic depreciation, maintenance, and supplies. A quantitative analysis of all hospital costs was applied directly to each patient encounter for comparative financial analyses.

RESULTS

Mean predicted risk of mortality was similar in both the robotic (n = 91) and sternotomy (n = 91) groups (0.9% vs 0.8%; P > .431). The total costs of robotic mitral operations were similar to those of sternotomy ($27,662 vs $28,241; P = .273). Early direct costs were higher in the robotic group. There was a marked increase in late indirect cost with the sternotomy cohort related to increased length of stay, transfusion requirements, and readmission rates. Robotic repair technique was associated with no echocardiographic recurrence greater than trace to only mild regurgitation at 1 year.

CONCLUSIONS

Experienced mitral surgeons can initiate a robotic program in a cost-neutral manner that maintains clinical outcome integrity as well as repair durability.

Для цитирования: Coyan Garrett, Wei Lawrence M, Althouse Andrew, Roberts Harold G, Schauble Drew, Murashita Takashi, Cook Chris C, Rankin J Scott, Badhwar Vinay. Robotic mitral valve operations by experienced surgeons are cost-neutral and durable at 1 year.. The Journal of thoracic and cardiovascular surgery. 2018. DOI: 10.1016/j.jtcvs.2018.03.147.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.