MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2018.04.025

Медицинская библиотека · International journal of cardiology · 2018

Galectin-3 is associated with left ventricular reverse remodeling and outcome after percutaneous mitral valve repair.

Zuern Christine S, Floss Niklas, Mueller Iris I, Eick Christian, Duckheim Martin, Patzelt Johannes, Gawaz Meinrad, May Andreas E, Mueller Karin A L

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Plasma Galectin-3 is a marker of myocardial inflammation and fibrosis, was associated with left ventricular (LV) reverse remodeling after conventional surgical mitral valve repair (MVR) and predicted clinical events in patients undergoing transcatheter aortic valve replacement (TAVR). We aimed to evaluate the association between pre-interventional Galectin-3 levels and (1) reverse LV remodeling and (2) major adverse cardiovascular events (MACE) in patients undergoing percutaneous MVR.

METHODS

Forty-four consecutive patients (median age 79 years, LV ejection fraction 39.5 ± 11.4%, 91% in NYHA functional class ≥III) with symptomatic moderate to severe mitral regurgitation undergoing percutaneous MVR were prospectively included. Plasma Galectin-3 levels were measured before the procedure. Echocardiographic and clinical assessment was performed at baseline and after 3 months. LV reverse remodeling was prospectively defined as a ≥10% increase in global longitudinal strain. MACE included death, myocardial infarction, heart failure related rehospitalization and stroke and was assessed after a mean follow-up time of 2 years.

RESULTS

72.7% of the patients showed LV reverse remodeling. Pre-interventional Galectin-3 < 10 ng/ml was an independent predictor of LV reverse remodeling (OR 10.3, 95% CI 1.2-83.9, p = 0.036). 25 patients (56.8%) experienced a MACE. Patients with Galectin-3 levels ≥ 10 ng/ml had significantly more MACE than patients with Galectin-3 levels < 10 ng/ml (100% vs. 45.5%, p = 0.003). Diabetes independently predicted MACE (HR 3.1, 95% CI 1.0-9.4, p = 0.049); Galectin-3 ≥ 10 ng/ml was of borderline significance (HR 2.2, 95% CI 0.9-5.4, p = 0.088).

CONCLUSIONS

Pre-interventional plasma Galectin-3 levels are associated with LV reverse remodeling and with clinical outcome after percutaneous MVR.

Для цитирования: Zuern Christine S, Floss Niklas, Mueller Iris I, Eick Christian, Duckheim Martin, Patzelt Johannes, Gawaz Meinrad, May Andreas E, Mueller Karin A L. Galectin-3 is associated with left ventricular reverse remodeling and outcome after percutaneous mitral valve repair.. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2018.04.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.