MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2018.01.012

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2018

Transcatheter Mitral Valve Repair Using the Edge-to-Edge Clip.

Nyman Charles B, Mackensen G Burkhard, Jelacic Srdjan, Little Stephen H, Smith Thomas W, Mahmood Feroze

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Percutaneous intervention for mitral valve (MV) disease has been established as an alternative to open surgical MV repair in patients with prohibitive surgical risk. Multiple percutaneous approaches have been described and are in various stages of development. Edge-to-edge leaflet plication with the MitraClip (Abbott, Menlo Park, CA) is currently the only Food and Drug Administration-approved device specifically for primary or degenerative lesions. Use of the edge-to-edge clip for secondary mitral regurgitation is currently under investigation and may result in expanded indications. Echocardiography has significantly increased our understanding of the anatomy of the MV and provided us with the ability to classify and quantify the associated mitral regurgitation. For percutaneous interventions of the MV, transesophageal echocardiography imaging is used for patient screening, intraprocedural guidance, and confirmation of the result. Optimal outcomes require the echocardiographer and the proceduralist to have a thorough understanding of intra-atrial septal and MV anatomy, as well as an appreciation for the key points and potential pitfalls of each of the procedural steps. With increasing experience, more complex valvular pathology can be successfully percutaneously treated. In addition to two-dimensional echocardiography, advances in three-dimensional echocardiography and fusion imaging will continue to support the refinement of current technologies, the expansion of clinical applications, and the development of novel devices.

Для цитирования: Nyman Charles B, Mackensen G Burkhard, Jelacic Srdjan, Little Stephen H, Smith Thomas W, Mahmood Feroze. Transcatheter Mitral Valve Repair Using the Edge-to-Edge Clip.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2018. DOI: 10.1016/j.echo.2018.01.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.