MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/joic.12392

Медицинская библиотека · Journal of interventional cardiology · 2017

Long-term clinical results of bioresorbable absorb scaffolds using the PSP-technique in patients with and without diabetes.

Markovic Sinisa, Kugler Christine, Rottbauer Wolfgang, Wöhrle Jochen

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We evaluated clinical results up to 36 months after implantation of Absorb BVS using PSP-technique and compared the outcome of patients with and without diabetes mellitus.

BACKGROUND

Absorb II demonstrated that interventional treatment of coronary artery disease with bioresorbable vascular scaffolds (BVS) without proper PSP-technique (pre-dilation, proper sizing, and post-dilation) is associated with an increased thrombotic risk, even in simple lesions.

METHODS

In this prospective study 319 patients with 420 lesions were enrolled and treated with the Absorb BVS. Pre-dilation was mandatory and post-dilation with a high-pressure balloon was performed in patients with a scaffold length >12 mm. Patients were clinically followed up to 3 years. Primary outcome measure was the device-oriented endpoint (DoCE) defined as cardiac death, myocardial infarction not clearly related to a non-target vessel and target lesion revascularization.

RESULTS

DoCE was 5.0%, 7.1%, and 10.0% after 12, 24, and 36 months for the total population. Rate of scaffold thrombosis was 0.5%, 0.8%, and 1.4% after 12, 24, and 36 months. Rate of DoCE was higher in the diabetic subgroup with 9.1%, 12.6%, and 12.9% after 12, 24, and 36 months compared with 4.0% (P = 0.13), 5.6% (P = 0.05), and 9.9% (P = 0.20) in patients without diabetes mellitus.

CONCLUSIONS

Patients treated with the Absorb BVS using the PSP-technique show good results up to 3 years with a low rate of scaffold thrombosis. Patients suffering from diabetes mellitus have an increased rate of DoCE compared with non-diabetic patients.

CLINICAL TRIAL REGISTRATION: clinicaltrials.gov_NCT02162056.

Для цитирования: Markovic Sinisa, Kugler Christine, Rottbauer Wolfgang, Wöhrle Jochen. Long-term clinical results of bioresorbable absorb scaffolds using the PSP-technique in patients with and without diabetes.. Journal of interventional cardiology. 2017. DOI: 10.1111/joic.12392.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.