Right ventricular pacemaker lead position is associated with differences in long-term outcomes and complications.

Witt Chance M, Lenz Charles J, Shih Henry H, Ebrille Elisa, Rosenbaum Andrew N, van Zyl Martin, Aung Htin, Manocha Kevin K, Deshmukh Abhishek J, Hodge David O, Mulpuru Siva K, Cha Yong-Mei, Espinosa Raul E, Asirvatham Samuel J, Mcleod Christopher J

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Cardiac pacing from the right ventricular apex is associated with detrimental long-term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long-term outcomes and lead-related complications associated with differing ventricular lead tip position.

METHODS AND

RESULTS

All adult patients who underwent dual-chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long-term outcomes and lead-related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).

CONCLUSIONS

Septal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.

Для цитирования: Witt Chance M, Lenz Charles J, Shih Henry H, Ebrille Elisa, Rosenbaum Andrew N, van Zyl Martin, Aung Htin, Manocha Kevin K, Deshmukh Abhishek J, Hodge David O, Mulpuru Siva K, Cha Yong-Mei, Espinosa Raul E, Asirvatham Samuel J, Mcleod Christopher J. Right ventricular pacemaker lead position is associated with differences in long-term outcomes and complications.. Journal of cardiovascular electrophysiology. 2017. DOI: 10.1111/jce.13256.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.