m+Medelevator.RU
← Поиск публикаций
Circulation research · 2017

Hemodynamic Support With a Microaxial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Flaherty Michael P, Pant Sadip, Patel Samir V, Kilgore Tyler, Dassanayaka Sujith, Loughran John H, Rawasia Wasiq, Dawn Buddhadeb, Cheng Allen, Bartoli Carlo R

Аннотация

RATIONALE: Acute kidney injury (AKI) is common during high-risk percutaneous coronary intervention (PCI), particularly in those with severely reduced left ventricular ejection fraction. The impact of partial hemodynamic support with a microaxial percutaneous left ventricular assist device (pLVAD) on renal function after high-risk PCI remains unknown.

OBJECTIVE: We tested the hypothesis that partial hemodynamic support with the Impella 2.5 microaxial pLVAD during high-risk PCI protected against AKI.

METHODS AND RESULTS: In this retrospective, single-center study, we analyzed data from 230 patients (115 consecutive pLVAD-supported and 115 unsupported matched-controls) undergoing high-risk PCI with ejection fraction ≤35%. The primary outcome was incidence of in-hospital AKI according to AKI network criteria. Logistic regression analysis determined the predictors of AKI. Overall, 5.2% (6) of pLVAD-supported patients versus 27.8% (32) of unsupported control patients developed AKI (P<0.001). Similarly, 0.9% (1) versus 6.1% (7) required postprocedural hemodialysis (P<0.05). Microaxial pLVAD support during high-risk PCI was independently associated with a significant reduction in AKI (adjusted odds ratio, 0.13; 95% confidence intervals, 0.09-0.31; P<0.001). Despite preexisting CKD or a lower ejection fraction, pLVAD support protection against AKI persisted (adjusted odds ratio, 0.63; 95% confidence intervals, 0.25-0.83; P=0.04 and adjusted odds ratio, 0.16; 95% confidence intervals, 0.12-0.28; P<0.001, respectively).

CONCLUSIONS: Impella 2.5 (pLVAD) support protected against AKI during high-risk PCI. This renal protective effect persisted despite the presence of underlying CKD and decreasing ejection fraction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты