OBJECTIVE

We sought to compare the new transcatheter aortic valve replacement (TAVR) device ACURATE neo (ACT) with the already established CoreValve (MCV) and SAPIEN XT (SXT) for the treatment of severe aortic stenosis (AS).

BACKGROUND

Very few data on TAVR devices are available beyond MCV and SAPIEN and there is no previous study comparing ACT with MCV and SXT.

METHODS

We prospectively evaluated consecutive patients who underwent transfemoral TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria.

RESULTS

A total of 162 patients (ACT n = 49, MCV n = 56, SXT n = 57), were included. MCV group had higher valve embolization/migration rates (ACT none; MCV 9%; SXT 2%; P = 0.034) causing lower device success rates (ACT 98%; MCV 86%; SXT 95%; P = 0.043). At 30 days, there was no significant difference in all-cause mortality (P = 0.22), cardiovascular mortality (P = 0.20), periprocedural myocardial infarction (P = 0.40), stroke (P = 0.64), major vascular complications (P = 0.48), life-threatening bleeding (P = 0.29), acute kidney injury stage 2/3 (P = 0.69), or VARC-2 composite early safety endpoints (P = 0.21). MCV group had higher rates of new permanent pacemaker implantation (ACT 6%; MCV 25%; SXT 11%; P = 0.013). Follow-up echocardiography showed no significant difference in aortic valve mean pressure gradient (P = 0.73) or moderate/severe aortic regurgitation (P = 0.19) between groups.

CONCLUSIONS

In a "real world" registry, ACT compared favorably against the well-studied SXT and MCV devices in both safety and efficacy. MCV implantation was associated with lower device success rates and higher rates of new permanent pacemaker implantation. © 2016 Wiley Periodicals, Inc.

Для цитирования: Jatene Tannas, Castro-Filho Antonio, Meneguz-Moreno Rafael A, Siqueira Dimytri A, Abizaid Alexandre A C, Ramos Auristela I O, Arrais Magaly, Le Bihan David C S, Barretto Rodrigo B M, Moreira Adriana C, Sousa Amanda G M R, Eduardo Sousa J. Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016. DOI: 10.1002/ccd.26837.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.