OBJECTIVES

We sought to compare the procedural implications of using bioresorbable everolimus-eluting scaffolds (BVS) and Pt-Cr everolimus-eluting stent with abluminal bioabsorbable polymer (Synergy).

BACKGROUND

There are important differences in the respective platforms, which could impact on procedural performance, complications and outcomes.

METHODS

A prospective, randomized single center study including consecutive patients in stable clinical condition and with lesions amenable to be treated with BVS according to predefined criteria. Patients were randomized to either treatment with BVS or Synergy. All procedural data were collected and 12 months clinical follow up conducted. Primary objectives were fluoroscopy time, median dose-area product, contras agent volumen, and peri-procedural troponin release.

RESULTS

A total of 200 patients were included, 100 in BVS group and 100 in Synergy group. No significant differences were observed in baseline clinical and angiographic characteristics. Predilatation (97.6 vs. 25.4%; P < 0.001), postdilatation (64.8 vs. 38.4%: P < 0.01), and use of 2 wires (20.8 vs. 10%; P = 0.02) were more frequent with BVS. The BVS group showed a significant increase in fluoroscopy time (18%), dose-area product (20%), and contrast volume (10%). Post-procedural increase of creatinine was similar and amount of TnI release was significantly higher with BVS but incidence of peri-procedural infarction was comparable. Clinical outcomes at 12 months were similar with definite thrombosis being 1% with BVS and 0% with Synergy.

CONCLUSIONS

The use of BVS in comparison with the Synergy stent in a similar lesional setting is associated with a higher use of resources in the procedure, more radiation, and higher TnI release. © 2016 Wiley Periodicals, Inc.

Для цитирования: de la Torre Hernandez Jose M, Garcia Camarero Tamara, Lee Dae-Hyun, Sainz Laso Fermin, Veiga Fernandez Gabriela, Pino Tania, Rubio Silvia, Legarra Pablo, Valdivia Jorge R, Zueco Gil Javier. Procedural resources utilization and clinical outcomes with bioresorbable everolimus-eluting scaffolds and Pt-Cr everolimus-eluting stent with resorbable abluminal polymer in clinical practice. A randomized trial.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016. DOI: 10.1002/ccd.26843.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.