Heart (British Cardiac Society) · 2016

Kidney function and appropriateness of device therapies in adults with implantable cardioverter defibrillators.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bansal Nisha, Szpiro Adam, Masoudi Frederick, Greenlee Robert T, Smith David H, Magid David J, Gurwitz Jerry H, Reynolds Kristi, Tabada Grace H, Sung Sue Hee, Dighe Ashveena, Cassidy-Bushrow Andrea, Garcia-Montilla Romel, Hammill Stephen, Hayes John, Kadish Alan, Sharma Param, Varosy Paul, Vidaillet Humberto, Go Alan S

Аннотация

OBJECTIVE: Patients with chronic kidney disease (CKD) have higher risk of sudden cardiac death; however, they may not receive implantable cardioverter defibrillators (ICDs), in part due to higher risk of complications. We evaluated whether CKD is associated with greater risk of device-delivered shocks/antitachycardia pacing (ATP) therapies among patients receiving a primary prevention ICD.

METHODS: We studied participants in the observational Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter Defibrillators. CKD was defined as estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2. Outcomes included all delivered shocks/ATPs therapies and type of shock/ATP therapies (inappropriate or appropriate, determined by physician adjudication) within the 3 years. We evaluated the associations between CKD and time to first device therapy, burden of device therapy, and inappropriate versus appropriate device therapy, adjusting for demographics, comorbidity, laboratory values and medication use.

RESULTS: Among 2161 participants, 1066 (49.3%) had CKD (eGFR 44±11 mL/min/1.73 m2) at ICD implantation. During mean of 2.26±0.89 years, 9.8% and 18.5% of participants had at least one inappropriate and appropriate shock/ATP therapies, respectively. CKD was not associated with time to first shock/ATP therapies (adjusted HR 0.87, 95% CI 0.73 to 1.05), overall burden of shock/ATP therapies (adjusted relative rate 0.93, 95% CI 0.74 to 1.17) or inappropriate versus appropriate shock/ATP therapies (adjusted relative risk 0.88, 95% CI 0.68 to 1.14) compared with not having CKD.

CONCLUSIONS: In adults receiving a primary prevention ICD, mild-to-moderate CKD was not associated with the timing, burden or appropriateness of subsequent device therapy. Potential concern for inappropriate ICD-delivered therapies should not preclude ICDs among eligible patients with CKD.