Laparoscopic azygoportal disconnection procedure with a bipolar feedback controlled sealing system in a porcine model.

Shamiyeh A, Hubmann R, Benkö L, Vattay P, Röth E, Tulipan L, Wayand W U, Danis J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To examine the feasibility of a new, minimally invasive procedure for the devascularization of the proximal stomach and distal esophagus to prevent recurrent variceal bleeding in portal hypertension in a new animal model.

MATERIAL AND

METHODS

Portal hypertension was created by laparoscopic clip ligation of the portal vein on 20 pigs. After 2 weeks the azygoportal disconnection procedure was performed with the LigaSure-ATLAS instrument.

RESULTS

There were 16 pigs out of 20 that survived both operations. Two died during introduction of anesthesia, one because of a cardiac arrest (second operation). One pig died resulting from necrosis of the gastric and esophageal wall. Autopsy (2 weeks later) showed that there was a complete arterial devascularization. At autopsy, none of the remaining 16 pigs had esophageal varices or necrosis of the stomach or esophagus.

CONCLUSION

Laparoscopic azygoportal disconnection is a less invasive method for the prevention of rebleeding and seems to be safely performed with the LigaSure-ATLAS instrument.

Для цитирования: Shamiyeh A, Hubmann R, Benkö L, Vattay P, Röth E, Tulipan L, Wayand W U, Danis J. Laparoscopic azygoportal disconnection procedure with a bipolar feedback controlled sealing system in a porcine model.. The Journal of surgical research. 2005. DOI: 10.1016/j.jss.2005.07.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.