MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diabres.2021.108876

Медицинская библиотека · Diabetes research and clinical practice · 2021

An analysis of Medtronic MiniMed 670G insulin pump use in clinical practice and the impact on glycemic control, quality of life, and compliance.

Horowitz Maxwell E, Kaye William A, Pepper Gary M, Reynolds Kathryn E, Patel Shital R, Knudson Kort C, Kale Geetanjali K, Gutierrez Maria E, Cotto Leslie A, Horowitz Barry S

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: This study evaluated the use of the Medtronic MiniMed 670G system in adults with type 1 diabetes mellitus from a large endocrinology practice and its impact on glycemic control, quality of life (QoL), compliance and safety.

METHODS

84 participants completed one site visit for data collection. Percentage of time in range (TIR: 70-180 mg/dL), hyperglycemia or time above range (TAB) (>180 mg/dL), hypoglycemia or time below range (TBR) (<70 mg/dL), HbA1c, average blood glucose (ABG), and other metrics were evaluated at the last visit using the system (LVMM) and compared between the last visit on previous insulin therapy (LVPT).

RESULTS

The mean percentage of TIR at the LVMM was 74.0 ± 12.1%, with an increase of 27.1% (p < 0.001) in TIR from the LVPT. The mean percentage of TAR was 22.9 ± 11.8% and the mean percentage of TBR was 3.2 ± 5.1%.

CONCLUSIONS

The use of the Medtronic MiniMed 670G system in our practice resulted in a TIR above the recommended target with a high degree of treatment satisfaction and compliance in adults with type 1 diabetes. Furthermore, the system may be a reasonable choice for patients struggling with significant amounts of hypoglycemia.

Для цитирования: Horowitz Maxwell E, Kaye William A, Pepper Gary M, Reynolds Kathryn E, Patel Shital R, Knudson Kort C, Kale Geetanjali K, Gutierrez Maria E, Cotto Leslie A, Horowitz Barry S. An analysis of Medtronic MiniMed 670G insulin pump use in clinical practice and the impact on glycemic control, quality of life, and compliance.. Diabetes research and clinical practice. 2021. DOI: 10.1016/j.diabres.2021.108876.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.