DOI 10.3390/jcm11154570

Медицинская библиотека · Journal of clinical medicine · 2022

Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis.

Potratz Max, Mohemed Kawa, Omran Hazem, Gortamashvili Lasha, Friedrichs Kai Peter, Scholtz Werner, Scholtz Smita, Rudolph Volker, Piper Cornelia, Gilis-Januszewski Tomasz, Schramm René, Furukawa Nobuyuki, Gummert Jan, Bleiziffer Sabine, Rudolph Tanja Katharina

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients.

METHODS

From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients.

RESULTS

At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable.

CONCLUSIONS

In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.

Для цитирования: Potratz Max, Mohemed Kawa, Omran Hazem, Gortamashvili Lasha, Friedrichs Kai Peter, Scholtz Werner, Scholtz Smita, Rudolph Volker, Piper Cornelia, Gilis-Januszewski Tomasz, Schramm René, Furukawa Nobuyuki, Gummert Jan, Bleiziffer Sabine, Rudolph Tanja Katharina. Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis.. Journal of clinical medicine. 2022. DOI: 10.3390/jcm11154570.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.