Multi-Center Comparison of Two Self-Expanding Transcatheter Heart Valves: A Propensity Matched Analysis.

Blumenstein Johannes, Eckel Clemens, Husser Oliver, Kim Won-Keun, Renker Matthias, Choi Yeong-Hoon, Hamm Christian W, Al-Terki Hani, Sötemann Dagmar, Körbi Leon, Tiyerili Vedat, Grothusen Christina, Gaede Luise, Dohmen Guido, Möllmann Helge

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

During the last years, several transcatheter aortic heart valves entered the clinical market and are commercially available. The prostheses differ regarding several technical and functional aspects. However, little is known regarding head-to-head comparative data of the ACURATE neo and the PORTICO valve prostheses.

OBJECTIVES

The aim of this study was to compare two self-expanding transcatheter aortic heart valves (THV), the ACURATE neo and the PORTICO, with regard to in-hospital and 30-day outcomes, as well as early device failures.

METHODS

A total of 1591 consecutive patients with severe native aortic valve stenosis from two centers were included in the analyses and matched by 1:1 nearest neighbor matching to identify one patient treated with PORTICO (n = 344) for each patient treated with ACURATE neo (n = 344).

RESULTS

In-hospital complications were comparable between both valves, including any kind of stroke (ACURATE neo = 3.5% vs. PORTICO = 3.8%; p = 1.0), major vascular complications (ACURATE neo = 4.5% vs. PORTICO = 5.4%; p = 0.99) or life-threatening bleeding (ACURATE neo = 1% vs. PORTICO = 2%; p = 0.68). The rate of device failure defined by the VARC-2 criteria were comparable, including elevated gradients and moderate-to-severe paravalvular leakage (ACURATE neo = 7.3% vs. PORTICO = 7.6%; p = 1.0). However, the need for permanent pacemaker implantation (PPI) was significantly more frequent after the use of PORTICO THV (9.5% vs. 18.7%; p = 0.002).

CONCLUSIONS

In this two-center case-matched comparison, short-term clinical and hemodynamic outcomes showed comparable results between PORTICO and ACURATE neo prostheses. However, PORTICO was associated with a significant higher incidence of PPI.

Для цитирования: Blumenstein Johannes, Eckel Clemens, Husser Oliver, Kim Won-Keun, Renker Matthias, Choi Yeong-Hoon, Hamm Christian W, Al-Terki Hani, Sötemann Dagmar, Körbi Leon, Tiyerili Vedat, Grothusen Christina, Gaede Luise, Dohmen Guido, Möllmann Helge. Multi-Center Comparison of Two Self-Expanding Transcatheter Heart Valves: A Propensity Matched Analysis.. Journal of clinical medicine. 2022. DOI: 10.3390/jcm11144228.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.