The hemodynamic performance of balloon-expandable aortic bioprostheses in the elderly: a comparison between rapid deployment and transcatheter implantation.

Iacovelli Fortunato, Desario Paolo, Cafaro Alessandro, Pignatelli Antonio, Alemanni Rossella, Montesanti Rosamaria, Bortone Alessandro Santo, De Cillis Emanuela, De Palo Micaela, Bardi Luca, Martinelli Gian Luca, Tesorio Tullio, Cassese Mauro, Contegiacomo Gaetano

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Surgical aortic valve replacement with a rapid deployment valve (RDV) is a relatively recent treatment option. The aim of this study was to compare the hemodynamic performance of balloon-expandable (BE)-RDVs and BE-transcatheter heart valves (THVs) in a high surgical risk and frail-elderly population.

METHODS

BE-THVs and BE-RDVs were implanted in 138 and 47 patients, respectively, all older than 75 years and with a Canadian Study of Health and Aging category of 5 or above. Echocardiographic assessment was performed at discharge and six months later.

RESULTS

At discharge, transprosthetic pressure gradients and indexed effective orifice area (iEOA) were similar in both cohorts. At six-month follow-up, BE-RDVs showed lower peak (14.69 vs. 20.86 mmHg; p < 0.001) and mean (7.82 vs. 11.83 mmHg; p < 0.001) gradients, and larger iEOA (1.05 vs. 0.84 cm2/m2; p < 0.001). Similar findings were also shown considering only small-sized valves. Moderate-to-severe paravalvular leakage was more prevalent in BE-THVs at discharge (14.49 vs. 0.00%; p = 0.032) and, considering exclusively small prostheses, at six months too (57.69 vs. 15.00%; p = 0.014). Nevertheless, BE-THVs determined amelioration in left ventricular ejection fraction (53.79 vs. 60.14%; p < 0.001), pulmonary artery systolic pressure (35.81 vs. 33.15 mmHg; p = 0.042), and tricuspid regurgitation severity (40.58 vs. 19.57%; p = 0.031), from discharge to mid-term follow-up.

CONCLUSIONS

BE-RDVs showed better hemodynamic performance, especially when implanted in small annuli. Despite their worse baseline conditions, transcatheter patients still exhibited a greater improvement of their echocardiographic profile at mid-term follow-up.

Для цитирования: Iacovelli Fortunato, Desario Paolo, Cafaro Alessandro, Pignatelli Antonio, Alemanni Rossella, Montesanti Rosamaria, Bortone Alessandro Santo, De Cillis Emanuela, De Palo Micaela, Bardi Luca, Martinelli Gian Luca, Tesorio Tullio, Cassese Mauro, Contegiacomo Gaetano. The hemodynamic performance of balloon-expandable aortic bioprostheses in the elderly: a comparison between rapid deployment and transcatheter implantation.. Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese. 2022. DOI: 10.1016/j.hjc.2022.07.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.