Mid-term impact of underfilling and overfilling of the SAPIEN 3 balloon-expandable transcatheter aortic valve implantation on mortality and valve function.

Ishizu Kenichi, Shirai Shinichi, Tashiro Hiroaki, Kitano Kazuki, Tabata Hiroyuki, Morofuji Toru, Nakamura Miho, Murakami Naoto, Morinaga Takashi, Hayashi Masaomi, Isotani Akihiro, Arai Yoshio, Ohno Nobuhisa, Kakumoto Shinichi, Ando Kenji

СтатьяПеревод пока не подготовлен

Аннотация

At present, underfilling or overfilling the volume of the balloon-expandable transcatheter heart valve (THV) is generally utilized in transcatheter aortic valve implantation (TAVI). However, no research has assessed the clinical impact of filling volume variations of the current-generation SAPIEN 3 THV. We analyzed the clinical data of 331 patients who underwent TAVI with SAPIEN 3 at our institution. Post-procedural echocardiographic and multidetector computed tomography (MDCT) scan data and 3-year prognoses according to each filling volume were assessed. The procedural outcomes and 3-year mortality rates were comparable among the underfilling, nominal filling, and overfilling groups. For all THV sizes, the THV area evaluated on post-procedural MDCT scan increased stepwise along with an elevated filling volume, thereby covering a wide range of native annulus area. Compared with patients in the nominal filling and overfilling groups, those with 23-mm THVs in the underfilling group had a smaller effective orifice area (EOA) (1.38 [IQR: 1.18-1.56] vs. 1.57 [IQR: 1.41-1.84] vs. 1.58 [IQR: 1.45-1.71] cm2, P = 0.02) and a higher mean transvalvular gradient (13.6 [IQR: 11.0-15.7] vs. 12.1 [IQR: 9.0-14.9] vs. 12.0 [IQR: 8.1-14.8] cm2, P = 0.04). In conclusion, by adjusting the filling volume of SAPIEN 3 using THV with limited sizes, continuously distributed native annulus areas were covered. The underfilling implantation technique had a minimal negative effect on the valve function of 23-mm THVs only. In the entire cohort, the filling volume variations did not affect the mid-term prognosis negatively.

Для цитирования: Ishizu Kenichi, Shirai Shinichi, Tashiro Hiroaki, Kitano Kazuki, Tabata Hiroyuki, Morofuji Toru, Nakamura Miho, Murakami Naoto, Morinaga Takashi, Hayashi Masaomi, Isotani Akihiro, Arai Yoshio, Ohno Nobuhisa, Kakumoto Shinichi, Ando Kenji. Mid-term impact of underfilling and overfilling of the SAPIEN 3 balloon-expandable transcatheter aortic valve implantation on mortality and valve function.. Heart and vessels. 2022. DOI: 10.1007/s00380-022-02109-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.