MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/meg.0000000000002400

Медицинская библиотека · European journal of gastroenterology & hepatology · 2022

Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference.

Fernandes Flavia, Piedade Juliana, Freitas Gabriela, Area Philippe, Santos Ricardo, Grinsztejn Beatriz, Veloso Valdilea, Pereira Gustavo, Perazzo Hugo

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We aimed to evaluate the agreement/accuracy of point shear-wave elastography (p-SWE) and 2D-shear-wave elastography (2D-SWE) for liver fibrosis staging using transient elastography (TE) as the reference.

METHODS

This retrospective study analyzed data from people with chronic liver diseases submitted to TE, p-SWE, and 2D-SWE. Liver fibrosis stages were defined using the TE's 'rule of five': normal (<5 kPa); suggestive of compensated-advanced chronic liver disease (cACLD) (10-15 kPa); highly suggestive of cACLD (15-20 kPa); suggestive of clinically significant portal hypertension (>20 kPa). Agreement and accuracy of p-SWE and 2D-SWE were assessed. Optimal cutoffs for p-SWE and 2D-SWE were identified using the point nearest to the upper left corner of the ROC curves.

RESULTS

A total of 289 participants were included. The correlation between TE and 2D-SWE (rho = 0.59; P < 0.001) or p-SWE (rho = 0.69; P < 0.001) was satisfactory. The AUROCs (95% CI) of 2D-SWE and p-SWE for TE ≥ 5 kPa; TE ≥ 10 kPa; TE ≥ 15 kPa and TE ≥ 20 kPa were 0.757 (0.685-0.829) and 0.741 (0.676-0.806); 0.819 (0.770-0.868) and 0.870 (0.825-0.915); 0.848 (0.803-0.893) and 0.952 (0.927-0.978); 0.851 (0.806-0.896) and 0.951 (0.920-0.982), respectively. AUROCs of 2D-SWE were significantly lower compared with p-SWE for detecting cACLD. Optimal thresholds of 2D-SWE and p-SWE for TE ≥ 15 kPa were 8.82 kPa (sensitivity = 86% and specificity = 79%) and 8.86 kPa (sensitivity = 90% and specificity = 92%), respectively.

CONCLUSION

LSM by p-SWE and 2D-SWE techniques were correlated with TE. LSM by p-SWE seems to be more accurate than 2D-SWE to identify patients with more advanced fibrosis.

Для цитирования: Fernandes Flavia, Piedade Juliana, Freitas Gabriela, Area Philippe, Santos Ricardo, Grinsztejn Beatriz, Veloso Valdilea, Pereira Gustavo, Perazzo Hugo. Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference.. European journal of gastroenterology & hepatology. 2022. DOI: 10.1097/meg.0000000000002400.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.