MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2022.07.013

Медицинская библиотека · JACC. Clinical electrophysiology · 2022

Simultaneous Entrainment Response Assessment at Multiple Sites.

Derejko Paweł, Podziemski Piotr, Bardyszewski Aleksander, Kuklik Paweł, Kuśnierz Jacek, Szumowski Łukasz Jan, Stępień Katarzyna, Dzwonkowska Dobromiła, Polańska-Skrzypczyk Magdalena, Walczak Franciszek, Żebrowski Jan Jacek, Pürerfellner Helmut

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The entrainment response, defined as the difference between the postpacing interval and the tachycardia cycle length (TCL) recorded from a mapping catheter, allows to track down the components of the tachycardia loop.

OBJECTIVES

The aim of this study was to evaluate if the postpacing interval measured simultaneously from multiple sites that are remote from the pacing site (PPIR) could be clinically useful in mapping re-entrant circuits.

METHODS

Ninety-two episodes of entrainment response in 29 patients with different macro-re-entrant tachycardias were evaluated using a standardized entrainment protocol. The spatial distribution of different values of PPIR-TCL in a simulation and a computational model of an entrained re-entrant tachycardia was also analyzed.

RESULTS

The PPIR exceeded TCL by more than 20 milliseconds only if both pacing and recording sites were outside the tachycardia circuit. The PPIR-TCL at in-circuit sites was always ≤20 milliseconds. Sites with negative PPIR-TCL values were found either outside or inside the tachycardia circuit.

CONCLUSIONS

Assessment of entrainment response from catheters remote from the pacing site may enhance spatial mapping of the tachycardia circuit. The PPIR-TCL above 20 milliseconds has an excellent positive predictive value in identifying sites outside the tachycardia circuit.

Для цитирования: Derejko Paweł, Podziemski Piotr, Bardyszewski Aleksander, Kuklik Paweł, Kuśnierz Jacek, Szumowski Łukasz Jan, Stępień Katarzyna, Dzwonkowska Dobromiła, Polańska-Skrzypczyk Magdalena, Walczak Franciszek, Żebrowski Jan Jacek, Pürerfellner Helmut. Simultaneous Entrainment Response Assessment at Multiple Sites.. JACC. Clinical electrophysiology. 2022. DOI: 10.1016/j.jacep.2022.07.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.