SAGE open medicine · 2013

Comparison of sequentially measured Aloka echo-tracking one-point pulse wave velocity with SphygmoCor carotid-femoral pulse wave velocity.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vriz Olga, Driussi Caterina, La Carrubba Salvatore, Di Bello Vitantonio, Zito Concetta, Carerj Scipione, Antonini-Canterin Francesco

Аннотация

OBJECTIVES: Recently, echo-tracking-derived measures of arterial stiffness have been introduced in clinical practice for the assessment of one-point pulse wave velocity. The purpose of this study was to find a relation between carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity, and to find a value of one-point carotid pulse wave velocity that predicts carotid-femoral pulse wave velocity higher than 12 m/s.

METHODS: A total of 160 consecutive subjects (112 male/48 female, mean age = 51.5 ± 14.1 years; 96 healthy, 44 hypertensives, 13 with aortic valve disease, and 7 with left ventricular dysfunction) were studied. Carotid-femoral pulse wave velocity was measured with the SphygmoCor system and one-point carotid pulse wave velocity with high-definition echo-tracking system (ProSound Alpha10; Aloka, Tokyo, Japan).

RESULTS: Both carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity correlated significantly with each other (r = 0.539, p < 0.001) and with age (one-point carotid pulse wave velocity r = 0.618, carotid-femoral pulse wave velocity r = 0.617, p < 0.0001 for both). Median value of carotid-femoral pulse wave velocity (7.2 m/s, 95% confidence interval = 6.2-8.9) was systematically higher than that of one-point carotid pulse wave velocity (5.8 m/s, 95% confidence interval = 5-6.6). The area under the receiver operating characteristic curve was 0.85, identifying the cutoff for one-point pulse wave velocity of 6.65 m/s as the best predictor of carotid-femoral pulse wave velocity more than 12 m/s (sensitivity = 0.818, specificity = 0.819).

CONCLUSIONS: One-point carotid pulse wave velocity correlates with carotid-femoral pulse wave velocity, and the cutoff of 6.65 m/s was the best predictor of carotid-femoral pulse wave velocity over 12 m/s.