MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2012-303095

Медицинская библиотека · Heart (British Cardiac Society) · 2012

Incidence, predictors and impact of bleeding after transcatheter aortic valve implantation using the balloon-expandable Edwards prosthesis.

Borz Bogdan, Durand Eric, Godin Matthieu, Tron Christophe, Canville Alexandre, Litzler Pierre-Yves, Bessou Jean-Paul, Cribier Alain, Eltchaninoff Hélène

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the incidence, predictors and impact of bleeding after transcatheter aortic valve implantation (TAVI).

DESIGN

Single-centre prospective observational study.

SETTING

Charles Nicolle University Hospital, Rouen, France.

INTERVENTIONS: We included 250 consecutive patients who underwent TAVI between May 2006 and October 2011. All procedures were performed using Edwards SAPIEN and SAPIEN XT valves via transfemoral (TF) and transapical (TA) routes. Surgical cutdown was used for TF access when implanting the SAPIEN valve, while percutaneous access was used for SAPIEN XT implantation. Life-threatening bleeding (LTB), major and minor bleeding and other complications were defined using Valve Academic Research Consortium criteria.

RESULTS

TAVI was performed via TF access in 190 cases (76%) and the SAPIEN XT valve was used in 123 cases (49.2%). Bleeding after TAVI was noted in 68 patients (27.2%): LTB in 33 (13.2%), major bleeding in 23 (9.2%) and minor bleeding in 12 (4.8%). By multivariate analysis, only TA access was an independent predictor of LTB (OR 3.7, 95% CI 1.73 to 7.9, p = 0.001). Patients presenting with LTB after TAVI had a higher 30-day mortality (33.3% vs 3.7%, p < 0.001) and 1-year mortality (54% vs 18%, p < 0.001). LTB was an independent predictive factor of 1-year mortality (HR 2.54, 95% CI 1.3 to 4.9, p = 0.002).

CONCLUSIONS

Bleeding is a frequent complication of TAVI, occurring in 27% of cases. LTB is associated with higher 30-day and 1-year mortality.

Для цитирования: Borz Bogdan, Durand Eric, Godin Matthieu, Tron Christophe, Canville Alexandre, Litzler Pierre-Yves, Bessou Jean-Paul, Cribier Alain, Eltchaninoff Hélène. Incidence, predictors and impact of bleeding after transcatheter aortic valve implantation using the balloon-expandable Edwards prosthesis.. Heart (British Cardiac Society). 2012. DOI: 10.1136/heartjnl-2012-303095.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.