MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00604-026-08217-x

Медицинская библиотека · Mikrochimica acta · 2026

A non-enzymatic sensor based on rGO/Pt NPs/Fc-Tyr/POPD nanocomposite for hydrogen peroxide determination in liver cancer tissues.

Xie Xixiang, Huang Rongping, Zhao Tao, Zhang Yaru, Wang Rongfang, Liu Xiyu, Xiao Qicai, He Jian, Wu Pan, Huang Yong

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Malignant tumors remain a major global health challenge, highlighting the need for rapid and sensitive analytical tools for investigating cancer-associated oxidative stress. In this study, we developed a non-enzymatic electrochemical hydrogen peroxide (H₂O₂) sensor based on a reduced graphene oxide/platinum nanoparticle/ferrocene-tyramine/poly(o-phenylenediamine) (rGO/Pt NPs/Fc-Tyr/POPD) nanocomposite. H₂O₂, although not a tumor-specific biomarker, is an important reactive oxygen species associated with oxidative stress in cancer-related systems. The proposed sensing platform integrates the high conductivity of rGO, the electrocatalytic activity of Pt NPs, the TSA-derived Fc-Tyr deposition strategy, and the anti-interference properties of POPD. The sensor exhibited two wide linear detection ranges (5.0 µM-570 µM and 570 µM-10.5 mM), a low detection limit of 1.18 µM, and a rapid response time of less than 5 s. In addition, the sensor demonstrated satisfactory selectivity, reproducibility, and stability. Compared to previously reported rGO/Pt-based H₂O₂ sensors, the present platform introduces a TSA-derived Fc-Tyr deposition strategy to facilitate interfacial electron transfer and increase the density of redox-active species. The sensor was successfully applied to monitoring H₂O₂ changes in cultured cancer cells and ex vivo tumor tissue-derived samples under chemically stimulated oxidative conditions. These findings suggest that the proposed system may provide a useful tool for investigating oxidative-stress-associated biological processes and electrochemical H₂O₂ determination.

Для цитирования: Xie Xixiang, Huang Rongping, Zhao Tao, Zhang Yaru, Wang Rongfang, Liu Xiyu, Xiao Qicai, He Jian, Wu Pan, Huang Yong. A non-enzymatic sensor based on rGO/Pt NPs/Fc-Tyr/POPD nanocomposite for hydrogen peroxide determination in liver cancer tissues.. Mikrochimica acta. 2026. DOI: 10.1007/s00604-026-08217-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.