Diagnostic performance of contrast-enhanced dual-energy spectral mammography (CESM): a retrospective study involving 644 breast lesions.

Travieso-Aja María Del Mar, Maldonado-Saluzzi Daniel, Naranjo-Santana Pedro, Fernández-Ruiz Claudia, Severino-Rondón Wilsa, Rodríguez Rodríguez Mario, Vega Benítez Víctor, Pérez-Luzardo Octavio

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the diagnostic performance of contrast-enhanced dual-energy spectral mammography (CESM) in comparison with that of full-field digital mammography (FFDM), either alone or accompanied with breast ultrasound (BUS) in a large series of patients/breast lesions (n = 644).

PATIENTS AND

METHODS

In this retrospective study, five radiologists evaluated the lesions by three imaging modalities: FFDM, FFDM + BUS, and CESM and compared the imaging to the gold standard (histopathology or clinical follow-up). Diagnostic performance parameters and receiver operating characteristic (ROC) curves of CESM were calculated and compared to those of FFDM or FFDM + BUS (McNemar's test). Additionally, the reliability of tumor size measurement by CESM was compared with the histopathological measurement.

RESULTS

The study included 218 benign and 426 malignant lesions. 85% of benign and 93% of malignant lesions were adequately identified using CESM. With respect to FFDM and FFDM + BUS, CESM significantly increased sensitivity to 93.2% (+ 10.7% and + 3.4%, respectively); specificity to 84.4% (+ 15.8% and + 1.7%, respectively); PPV to 92.3% (+ 26.8% and + 3.6%, respectively); NPV to 86.0% (+ 1.6% and + 1.8%, respectively); and accuracy to 90.2% (+ 15.8% and + 3.2%, respectively). In the ROC curves analyses, the comparison among the three AUC values was also statistically significant (p < 0.001). Good agreement between tumor diameters measured using CESM and histopathology was observed (Spearman's rank correlation, r = 0.891, p < 0.0001), although this technique tended to produce an overestimation of the size (+ 7 mm).

CONCLUSIONS

CESM has high diagnostic accuracy and can be considered as a useful technique for the assessment of breast lesions.

Для цитирования: Travieso-Aja María Del Mar, Maldonado-Saluzzi Daniel, Naranjo-Santana Pedro, Fernández-Ruiz Claudia, Severino-Rondón Wilsa, Rodríguez Rodríguez Mario, Vega Benítez Víctor, Pérez-Luzardo Octavio. Diagnostic performance of contrast-enhanced dual-energy spectral mammography (CESM): a retrospective study involving 644 breast lesions.. La Radiologia medica. 2019. DOI: 10.1007/s11547-019-01056-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.