Медицинская библиотека · Journal of cardiovascular medicine (Hagerstown, Md.) · 2010

Permanent pacemaker implantation after isolated aortic valve replacement: incidence, risk factors and surgical technical aspects.

Nardi Paolo, Pellegrino Antonio, Scafuri Antonio, Bellos Kyriakos, De Propris Silvia, Polisca Patrizio, Chiariello Luigi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Conducting system defects are common in patients with aortic valve disease. Aortic valve replacement may result in further conduction abnormalities requiring permanent pacemaker implantation. The aim of our study was to identify the incidence and predictors for postoperative 30-day permanent pacemaker implantation in patients undergoing isolated aortic valve replacement, and the effect of an accurate surgical technique in order to prevent permanent pacemaker implantation.

METHODS

Data from 261 consecutive patients (mean age 69 +/- 12 years, 136 men) undergoing isolated aortic valve replacement from January 2004 to January 2008 were analyzed retrospectively. Indications for aortic valve replacement were aortic valve stenosis (n = 156), stenoinsufficiency (n = 63), regurgitation (n = 42). Aortic bicuspid valve was present in 25% of cases (n = 64), redo operation was the indication in 7% (n = 18). Preoperative conducting system disease, defined as first-degree atrioventricular block, left or right bundle-branch block or left anterior hemiblock, was present in 25.6% (n = 67) of patients. An accurate surgical technique for debridement of calcific material was performed.

RESULTS

In-hospital mortality was 0.8% (2 out of 261 patients). Postoperatively, 8 out of 261 patients (3%) required permanent pacemaker implantation, for second-degree (n = 1) or complete atrioventricular block (n = 7). Incidence of permanent pacemaker implantation was similar for patients either with or without preoperative conducting system disease (25 vs. 25.7%, P = NS). Independent predictors of permanent pacemaker implantation were greater preoperative end-systolic diameter (P = 0.026) and left ventricular septum hypertrophy (P = 0.041).

CONCLUSIONS

Need of permanent pacemaker implantation after aortic valve replacement seems to be related more to preoperative advanced aortic valve disease rather than pre-existing conducting system abnormalities. An accurate surgical technique for aortic valve replacement probably helps to prevent further impairment of conducting system function requiring early postoperative permanent pacemaker implantation.

Для цитирования: Nardi Paolo, Pellegrino Antonio, Scafuri Antonio, Bellos Kyriakos, De Propris Silvia, Polisca Patrizio, Chiariello Luigi. Permanent pacemaker implantation after isolated aortic valve replacement: incidence, risk factors and surgical technical aspects.. Journal of cardiovascular medicine (Hagerstown, Md.). 2010. DOI: 10.2459/jcm.0b013e32832f9fde.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.