Intermittent acute aortic regurgitation of a mechanical bileaflet aortic valve prosthesis: diagnosis and clinical implications.

Cianciulli Tomás Francisco, Saccheri María Cristina, Lax Jorge Alberto, Guidoin Robert, Zhang Ze, Guerra Juan E, Prezioso Horacio Alberto, Vidal Luis A

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Intermittent aortic regurgitation (AR) is an unusual complication after a mechanical prosthetic replacement. We describe a rare case of intermittent dysfunction of a bileaflet mechanical aortic prosthetic valve in a 41-year-old man with a 21 mm Tri-technologies prosthetic valve implanted 4 years before. Transthoracic echocardiography (TTE) before discharge was normal and prosthesis-patient mismatch was ruled out. He was admitted to our hospital because of mild dyspnoea at effort. TTE revealed acute and severe intermittent AR. The patient underwent surgery, during which abnormal proliferation of subvalvular pannus overgrowth on the inflow aspect of the prosthesis was found impeding the normal closure of one of the discs of the prosthesis. The pannus formation was resected, the Tri-technologies prosthetic valve was prophylactic explanted and a 23 mm St Jude Medical bileaflet mechanical prosthesis valve was implanted. We describe the role of TTE and the limitation of the cinefluoroscopy in the diagnosis of Tri-technologies prosthetic dysfunction.

Для цитирования: Cianciulli Tomás Francisco, Saccheri María Cristina, Lax Jorge Alberto, Guidoin Robert, Zhang Ze, Guerra Juan E, Prezioso Horacio Alberto, Vidal Luis A. Intermittent acute aortic regurgitation of a mechanical bileaflet aortic valve prosthesis: diagnosis and clinical implications.. European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology. 2008. DOI: 10.1093/ejechocard/jen320.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.