MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2024.08.025

Медицинская библиотека · World neurosurgery · 2024

Radiographic Anatomy of the Common Carotid Artery for Direct Carotid Puncture.

Singh Rahul B, Domingo Ricardo A, Sandhu Sukhwinder J S, Ahmed Ahmed K, Rios-Zermeno Jorge, Ramos-Fresnedo Andres, Pullen Michael W, Virador Gabriel M, Perez-Vega Carlos, Martinez Santos Jaime L, Abello-Vaamonde Jorge A, Erben Young, Vibhute Prasanna, Gupta Vivek, Pirgousis Phillip, Tawk Rabih G

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Direct common carotid puncture (DCP) is conventionally used as a bailout technique in stroke patients. However, little is known about the relevant anatomy. Our objective was to examine the relationship of the common carotid artery (CCA) to surrounding structures based on different DCP trajectories passing through the artery's center.

METHODS

Fifty randomly selected head/neck CTAs were analyzed. The trajectory of DCP and relationship to the internal jugular vein (IJV) and thyroid were analyzed at 1 cm intervals above the clavicle on 7 axial sections. Using the trans-carotid sagittal plane as the 0° trajectory, we plotted 3 additional trajectories at 30° intervals and the relationship with the IJV and thyroid proximity was graded as following: 0=absent, 1=adjacent, and 2=crossing. The CCA tortuosity index was also analyzed for each vessel.

RESULTS

Analysis of 2800 trajectories across 100 CCAs showed that the IJV and thyroid were least encountered on the axial sections 2 cm above the clavicle, at 0° on the right (9 thyroids and 6 IJV), and at 90° on the left (0 Thyroids and 14 IJVs). The tortuosity index of the CCA was significantly lower above the clavicle than its entire length (P < 0.001).

CONCLUSIONS

DCP performed 2 cm above the clavicle at 0° on the right, and 90° on the left appears to minimize encounters with the IJV and thyroid gland, reducing potential complications. However, despite these findings, ultrasound guidance remains vital for DCP safety. Further focus on endovascular device safety in DCP is needed.

Для цитирования: Singh Rahul B, Domingo Ricardo A, Sandhu Sukhwinder J S, Ahmed Ahmed K, Rios-Zermeno Jorge, Ramos-Fresnedo Andres, Pullen Michael W, Virador Gabriel M, Perez-Vega Carlos, Martinez Santos Jaime L, Abello-Vaamonde Jorge A, Erben Young, Vibhute Prasanna, Gupta Vivek, Pirgousis Phillip, Tawk Rabih G. Radiographic Anatomy of the Common Carotid Artery for Direct Carotid Puncture.. World neurosurgery. 2024. DOI: 10.1016/j.wneu.2024.08.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.