m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2017

Plaque erosion delays vascular healing after drug eluting stent implantation in patients with acute coronary syndrome: An In Vivo Optical Coherence Tomography Study.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hu Sining, Wang Chao, Zhe Chunyang, Zhu Yinchun, Yonetsu Taishi, Jia Haibo, Hou Jingbo, Zhang Shaosong, Jang Ik-Kyung, Yu Bo

Аннотация

OBJECTIVES: To compare vascular healing after drug-eluting stent (DES) implantation between plaque rupture (PR) and plaque erosion (PE).

BACKGROUND: Vascular response after stent implantation in patients with PR has been extensively studied. Little is known about vascular healing after stent implantation in PE.

METHODS: Sixty-five ACS patients who received optical coherence tomography (OCT) imaging of the culprit lesions both before and after stent implantation at baseline as well as at 6 months were included in this study. Patients were divided into two groups: PR (n = 19) and PE (n = 24). Prestent thrombus burden and poststent intrastent structure (ISS) volume were analyzed during the index procedure. The ratio of uncovered to total stent struts per cross-section score (RUTTS) and neointimal thickness and area were measured at follow-up.

RESULTS: OCT imaging showed that compared with PR, PE showed a significantly lower prestent thrombus score (34.2 ± 19.2 vs. 68.6 ± 44.2, P = 0.009) at baseline and a smaller poststent ISS volume (0.7 ± 0.9 mm3 vs. 2.1 ± 1.9 mm3 , P = 0.019). At the 6-month follow-up, PE showed a higher incidence of RUTTS >0.3 (12.2 ± 14.4 vs. 2.0 ± 4.5%, P = 0.003), thinner neointimal thickness (0.05 ± 0.02 mm vs. 0.12 ± 0.08 mm, P = 0.002), and smaller neointimal area (0.5 ± 0.2 vs. 1.2 ± 0.9 mm2 , P = 0.004) compared with PR. In a multivariate logistic model, PE was identified as an independent predictor for RUTTS >0.3.

CONCLUSIONS: PE was associated with less favorable healing following DES implantation when compared to PR at 6 months, indicating longer dual-antiplatelet therapy may be necessary for patients with PE. © 2017 Wiley Periodicals, Inc.