MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12933-017-0500-3

Медицинская библиотека · Cardiovascular diabetology · 2017

Third generation drug eluting stent (DES) with biodegradable polymer in diabetic patients: 5 years follow-up.

Wiemer Marcus, Stoikovic Sinisa, Samol Alexander, Dimitriadis Zisis, Ruiz-Nodar Juan M, Birkemeyer Ralf, Monsegu Jacques, Finet Gérard, Hildick-Smith David, Tresukosol Damras, Novo Enrique Garcia, Koolen Jacques J, Barbato Emanuele, Danzi Gian Battista, NOBORI 2 investigators

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To report the long-term safety and efficacy data of a third generation drug eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus after a follow-up period of 5 years.

BACKGROUND

After percutaneous coronary intervention patients with diabetes mellitus are under higher risk of death, restenosis and stent thrombosis (ST) compared to non-diabetic patients.

METHODS

In 126 centers worldwide 3067 patients were enrolled in the NOBORI 2 registry, 888 patients suffered from diabetes mellitus (DM), 213 of them (14%) being insulin dependent (IDDM). Five years follow-up has been completed in this study.

RESULTS

At 5 years, 89.3% of the patients were available for follow-up. The reported target lesion failure (TLF) rates at 5 years were 12.39% in DM group and 7.34% in non-DM group; (p < 0.0001). In the DM group, the TLF rate in patients with IDDM was significantly higher than in the non-IDDM subgroup (17.84 vs. 10.67%; p < 0.01). The rate of ST at 5 years was not different among diabetic versus non-diabetic patients or IDDM versus NIDDM. Only 10 (<0.4%) very late stent thrombotic events beyond 12 months occurred.

CONCLUSIONS

The Nobori DES performed well in patients with DM. As expected patients with DM, particularly those with IDDM, had worse outcomes. However, the very low rate of very late stent thrombosis in IDDM patients might have significant clinical value in the treatment of these patients. Clinical trial registration ISRCTN81649913; http://www.controlled-trials.com/isrctn/search.html?srch=81649913&sort=3&dir=desc&max=10.

Для цитирования: Wiemer Marcus, Stoikovic Sinisa, Samol Alexander, Dimitriadis Zisis, Ruiz-Nodar Juan M, Birkemeyer Ralf, Monsegu Jacques, Finet Gérard, Hildick-Smith David, Tresukosol Damras, Novo Enrique Garcia, Koolen Jacques J, Barbato Emanuele, Danzi Gian Battista, NOBORI 2 investigators. Third generation drug eluting stent (DES) with biodegradable polymer in diabetic patients: 5 years follow-up.. Cardiovascular diabetology. 2017. DOI: 10.1186/s12933-017-0500-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.