DOI 10.1016/j.ajic.2024.06.020
Effectiveness of ceiling-mounted ultraviolet-C lamps: An experimental study in a biocontainment unit of a tertiary care hospital.
Аннотация
BACKGROUND
We aimed to evaluate the performance of ceiling-mounted UV-C lamps.
METHODS
This study was conducted in an empty room with UV-C lamps in the biocontainment unit of a tertiary care hospital in South Korea. Each pathogen (Staphylococcus aureus, Escherichia coli, Candida krusei, Bacillus cereus, and Mycobacterium peregrinum) was inoculated on blood agar plates and placed in 20 selected places from the UV-C lamp, and irradiation was applied for 15 min. As a control group, the bacterial solution was diluted 10,000 times and UV was not applied.
RESULTS
A mean ± SD of 5.95 ± 0.91 log reduction was observed with UV irradiation compared with the control. The log reduction was greatest for S. aureus [median, 7.05 (IQR, 6.49-7.26)] and least for M. peregrinum [median, 4.88 (IQR, 4.58-5.24)]. The degree of log reduction was inversely proportional to the square of the distance from the UV-C lamp (R2 = -0.12, P < .001).
CONCLUSIONS
In this study, ceiling-mounted UV-C demonstrated effective disinfection of at least 4-log reduction of the test organisms within a 4-m distance. Mounted UV-C lighting is a considerable option for improving surface disinfection.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.