MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.nefroe.2024.11.024

Медицинская библиотека · Nefrologia · 2024

Intradialytic non-invasive hemodynamic monitoring: usefulness of cardiac preload values in predicting hemodynamic instability.

Rojo María Ángeles Fernández, Izquierdo Rafael Díaz-Tejeiro, Alonso Mario Vaquero, Rodríguez Dabaiba Regidor, Bravo Laura Cueto, Rodríguez Iván Carmena, Herrero David Carro, Reina Carlos Jesús Cabeza, Hormigos Francisco Javier Ahijado

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

Adequate control of patient blood volume in hemodialysis (HD) is essential as a modifiable risk factor for morbidity and mortality. In this study, we propose continuous non-invasive hemodynamic monitoring using bioreactance (Starling SV.Baxter) and real-time characterization of cardiac preload data to aid in the accurate assessment of volume status and improvement of tolerance in HD.

METHODOLOGY: Observational and prospective study on the relationship between cardiac preload data and intradialytic hemodynamic instability. Forty-six stable HD patients were recruited. Clinical, analytical, and dialysis data were collected from all participants. The protocol included bioimpedance (BIVA), pre- and post-dialysis echocardiography and tissue Doppler, and monitoring of hemodynamic parameters during the session.

RESULTS

According to the Fall20 definition, 24 patients (51.19%) experienced intradialytic hypotension (IDH). We found no relationship between IDH and analytical, echocardiographic, BIVA parameters, or relative blood volume measurement (BVM) values. Regarding hemodynamic monitoring, indexed systolic volume (ISV) was lower in patients with IDH (38.2 ± 0.9 vs. 39.2 ± 1.9; p < 0.001). Indexed systolic volume variation (ISVV) and heart rate (HR) were higher in the IDH group (14.1 ± 0.7 vs. 13.5 ± 0.7; p < 0.0001), (70.01 ± 2.1 vs. 68.97 ± 1.1; p < 0.0001), respectively. Indexed cardiac output (ICO) and indexed peripheral resistances (IPR) were also lower in the IDH group (2.62 ± 0.09 vs. 2.65 ± 0.13; p < 0.05) and (3201 ± 325 vs. 3432 ± 231; p < 0.05), respectively. Patients who started the session with lower preload (ΔSV after infusion of 250 cc ≥ 10%) more frequently developed IDH (p < 0.001).

CONCLUSIONS

Non-invasive hemodynamic monitoring and preload data may constitute a valid tool in managing the volume status of HD patients and preventing IDH.

Для цитирования: Rojo María Ángeles Fernández, Izquierdo Rafael Díaz-Tejeiro, Alonso Mario Vaquero, Rodríguez Dabaiba Regidor, Bravo Laura Cueto, Rodríguez Iván Carmena, Herrero David Carro, Reina Carlos Jesús Cabeza, Hormigos Francisco Javier Ahijado. Intradialytic non-invasive hemodynamic monitoring: usefulness of cardiac preload values in predicting hemodynamic instability.. Nefrologia. 2024. DOI: 10.1016/j.nefroe.2024.11.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.