m+Medelevator.RU
← Поиск публикаций
Clinical oral implants research · 2009

Five-year evaluation of the influence of keratinized mucosa on peri-implant soft-tissue health and stability around implants supporting full-arch mandibular fixed prostheses.

Клиническое исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schrott Alexander René, Jimenez Monik, Hwang Jae-Woong, Fiorellini Joseph, Weber Hans-Peter

Аннотация

BACKGROUND: The question of the importance of keratinized mucosa around dental implants for the prevention of peri-implant disease could not be answered in the relevant literature so far.

OBJECTIVE: To investigate the influence of peri-implant keratinized mucosa on long-term peri-implant soft-tissue health and stability over a period of 5 years.

MATERIAL AND METHODS: A total of 386 mandibular dental implants were placed in 73 completely edentulous patients, and subsequently restored with fixed full-arch prostheses. At prosthesis delivery (baseline) and after 3, 6, 12, 18, 24, 36, 48 and 60 months, modified plaque index (mPlI), modified sulcus bleeding index (mBI), distance between implant shoulder and mucosal margin (DIM) and width of peri-implant keratinized mucosa (KM) were recorded. Statistical analysis included multivariate logistic regression, multivariate ordinal logistic regression, generalized estimating equations and Bonferroni's correction.

RESULTS: Fifty-eight patients with 307 implants completed the 5-year study. Statistically significantly higher plaque accumulation on lingual sites (mean mPlI 0.67, SD 0.85), bleeding tendencies on lingual sites (mean mBI 0.22, SD 0.53) and larger soft-tissue recession on buccal sites (mean DIM -0.69 mm, SD 1.11 mm) were found when the width of KM was <2 mm, compared to sites with>or=2 mm of KM (mean mPlI 0.40, SD 0.68, P=0.001; mean mBI 0.13, SD 0.41, P<0.01; mean DIM -0.08 mm, SD 0.86 mm, P<0.001). The width of keratinized mucosa had no effect on bleeding tendency or plaque accumulation on buccal sites (P>0.05).

CONCLUSION: In patients exercising good oral hygiene and receiving regular implant maintenance therapy, implants with a reduced width of <2 mm of peri-implant keratinized mucosa were more prone to lingual plaque accumulation and bleeding as well as buccal soft-tissue recession over a period of 5 years.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты