MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The International journal of oral & maxillofacial implants · 2008

Influence of abutment material on stability of peri-implant tissues: a systematic review.

Linkevicius Tomas, Apse Peteris

СтатьяСистематический обзорПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this systematic review was to evaluate available evidence for a difference in the stability of peri-implant tissues between titanium abutments versus gold alloy, zirconium oxide, or aluminum oxide abutments.

MATERIALS AND

METHODS

Studies were identified by examining several electronic databases and major dental implant, prosthetic, and periodontal journals. To be selected for the preliminary article pool, the article must have been written in the English language and published from 1980 to March 2007. Articles were sorted based on the nature of the study. In vitro studies and literature reviews were excluded. The included articles were clinical, human histology, and animal studies. Case reports, case series, uncontrolled clinical trials, and clinical studies with teeth treated as a control were excluded from the final review.

RESULTS

The initial article pool included 40 articles of which 9 met the inclusion criteria: 3 animal studies, 2 human histological studies, and 4 randomized clinical trials. Soft tissue recession was not accurately measured in the included clinical studies. Assessment of peri-implant tissues around zirconium oxide and titanium abutments was described only in animal and human histologic studies. Due to differences in study types, timing of follow-ups, and outcome variables, meta-analysis could not be performed.

CONCLUSIONS

Included studies revealed that titanium abutments did not maintain a higher bone level in comparison to gold alloy, aluminum oxide, or zirconium oxide abutments. However, there is a lack of information about the clinical performance of zirconium oxide and gold alloy abutments as compared to titanium abutments.

Для цитирования: Linkevicius Tomas, Apse Peteris. Influence of abutment material on stability of peri-implant tissues: a systematic review.. The International journal of oral & maxillofacial implants. 2008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.