MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1600-051x.2008.01242.x

Медицинская библиотека · Journal of clinical periodontology · 2008

Single minimally invasive surgical technique with an enamel matrix derivative to treat multiple adjacent intra-bony defects: clinical outcomes and patient morbidity.

Cortellini Pierpaolo, Nieri Michele, Prato Giovanpaolo Pini, Tonetti Maurizio S

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: This case cohort study was designed to evaluate the clinical performance and the intra-operative and post-operative morbidity of the "minimally invasive surgical technique" (MIST) associated with the application of an enamel matrix derivative (EMD) in the treatment of multiple deep intra-bony defects in a single surgical procedure.

MATERIAL AND

METHODS

Forty-four deep intra-bony defects in 20 patients (>or=2 defects/patient) were surgically accessed with the MIST. This technique was designed to limit the mesio-distal flap extension and the apical flap reflection in order to reduce the surgical trauma and increase flap stability. The incision of the defect-associated papilla was performed according to the principles of the papilla preservation techniques. EMD was applied on the debrided and dried root surfaces. Stable primary closure of the flaps was obtained with modified internal mattress sutures. Surgery was performed with the aid of an operating microscope and microsurgical instruments. Clinical outcomes were collected at baseline and at 1 year. Intra-operative and post-operative morbidity was evaluated with questionnaires.

RESULTS

The 1-year clinical attachment level (CAL) gain was 4.4+/-1.4 mm (p<0.0001 compared with baseline). Seventy-three per cent of defects showed CAL improvements >or=4 mm. This corresponded to an 83+/-20% resolution of the defect (15 defects were completely filled). Residual probing pocket depths (PDs) were 2.5+/-0.6 mm. A minimal increase of 0.2+/-0.6 mm in gingival recession between baseline and 1 year was recorded. Twelve patients reported a mild perception of the hardship of the surgical procedure. Primary closure was obtained and maintained in all treated sites over time. Only six subjects reported moderate post-operative pain that lasted for 21+/-5 h.

CONCLUSIONS

These data indicate that a MIST in combination with EMD can be applied successfully for the treatment of multiple deep intra-bony defects in the same surgical procedure with excellent clinical outcomes and very limited patient morbidity.

Для цитирования: Cortellini Pierpaolo, Nieri Michele, Prato Giovanpaolo Pini, Tonetti Maurizio S. Single minimally invasive surgical technique with an enamel matrix derivative to treat multiple adjacent intra-bony defects: clinical outcomes and patient morbidity.. Journal of clinical periodontology. 2008. DOI: 10.1111/j.1600-051x.2008.01242.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.