Determinants of Glycemic Control with Automated Insulin Delivery in adults living with type 1 diabetes: A 12-Month Sub-Analysis of the French OB2F Registry.
Аннотация
OBJECTIVE
To identify baseline determinants of achieving international continuous glucose monitoring (CGM) targets after 12 months of automated insulin delivery (AID) in adults with type 1 diabetes.
RESEARCH DESIGN AND
METHODS
This predefined sub-analysis of the nationwide French OB2F registry included adults with type 1 diabetes initiating MiniMed 780G or Tandem Control-IQ in 2022. Participants required ≥14 consecutive days of CGM data at baseline and 12 months. The primary outcome was achievement of combined CGM targets at 12 months, defined as TIR >70% and TBR <4%. Baseline predictors were assessed using multivariable logistic regression.
RESULTS
Among 1,058 adults, 43% achieved combined CGM targets at 12 months (52% of MiniMed 780G users and 36% of Tandem Control-IQ users). Better baseline metabolic control, including higher TIR and lower HbA1c, TAR, GMI, and glucose variability, was independently associated with target achievement across both systems. Lower baseline TBR predicted target achievement only in MiniMed 780G users. GRI improved in both systems, from 44.1±19.4 to 30.2±13.6 with MiniMed 780G and from 49.4±20.0 to 36.7±14.9 with Tandem Control-IQ.
CONCLUSIONS
Baseline glycaemic profile is the main determinant of achieving international CGM targets after AID initiation in adults with type 1 diabetes, despite substantial improvement in those with poorer baseline control.