A prospective observational study on changes in endo-tracheal tube cuff pressure and its correlation with airway pressures during various stages of robotic pelvic surgeries.

Gupta Priyanka, Tandon Shipra, Dhar Mridul, Agarwal Ankit, Pathak Sharmishtha, Prabakaran P

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Robotic surgeries often require a relatively long duration of pneumo-peritoneum and trendelenburg position which may accentuate changes in endo-tracheal tube (ETT) cuff pressure leading to pressure related complications. The aim of this study was to analyze changes in ETT cuff pressures during various stages of pneumo-peritoneum and surgical positioning and its correlation with airway pressure changes.

MATERIAL AND

METHODS

A prospective observational study was planned after approval of institutional review board on 60 patients undergoing elective robotic pelvic surgery requiring head down position. Baseline cuff pressure was adjusted to 25 cm H2O. ETT cuff pressure, peak airway pressure and end tidal CO2 (ETCO2) was measured at various time intervals before and after pneumo-peritoneum and head down. Ventilatory parameters were kept fixed after baseline setting. Those requiring any change were excluded. Pearson's coefficient was used for correlation and ANOVA for trend of parameters at different time intervals (P value <0.05 was considered significant).

RESULTS

Baseline cuff pressure after manual inflation was 46.2 ± 17.4 cm H2O. Significant correlation was observed between change in cuff pressure and increase in peak airway pressure at the end of the surgery (r = 0.4, P < 0.05). Serial measurements of ETT cuff pressure, peak airway pressure and ETCO2 were significantly increased compared to baseline (P < 0.05).

CONCLUSION

Significant increases in ETT cuff pressure may be seen in robotic surgeries, with a positive correlation between change in cuff pressure and increase in airway pressures. Objective adjusted measurement of cuff pressure and airway pressures is recommended for such surgeries.

Для цитирования: Gupta Priyanka, Tandon Shipra, Dhar Mridul, Agarwal Ankit, Pathak Sharmishtha, Prabakaran P. A prospective observational study on changes in endo-tracheal tube cuff pressure and its correlation with airway pressures during various stages of robotic pelvic surgeries.. Journal of anaesthesiology, clinical pharmacology. 2022. DOI: 10.4103/joacp.joacp_325_20.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.