MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vec.13252

Медицинская библиотека · Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001) · 2022

Applicability of the drainage effectiveness of Blake drains and Tenckhoff catheters in the peritoneal dialysis of healthy rabbits (Oryctolagus cuniculus).

Pereira Ana Camila, Geraldes Silvano S, Maia Suellen R, de Azevedo Maria Gabriela P, da Silva Gustavo G, de Souza Bruna N, García Henry David M, Melchert Alessandra, Brandão Cláudia Valéria S, de Souza Fabiana F, Guimarães-Okamoto Priscylla T C

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the efficacy of dialysate drainage between Tenckhoff (TC) catheter and Blake (BL) in peritoneal dialysis (PD) in healthy rabbits.

DESIGN

Prospective experimental study.

SETTING

University Teaching Hospital and University research laboratory.

ANIMALS: Twenty healthy, male, New Zealand rabbits.

INTERVENTIONS: PD via the TC catheter and the BL abdominal drain was compared during 3 consecutive days of dialysis delivery.

MEASUREMENTS AND MAIN

RESULTS

One session of PD was performed per day for 3 consecutive days (S1: first session, S2: second session, S3: third session) and each session included 4 cycles of infusion, dwell of dialysate in the abdomen, and drainage. Data collection included daily urea, creatinine, alanine aminotransferase, albumin, and potassium, in addition to hematological parameters (eg, RBC, HCT, hemoglobin, WBC, and platelet count). Statistical analysis using a mixed linear model with multiple comparisons was performed. The BL drain resulted in an increase in volume drained (ml/kg) when compared to TC catheter on S2 (third and fourth cycles) and S3 (first and second cycles).

CONCLUSIONS

The BL drain proved to be superior to the TC catheter, being capable of draining a larger volume of dialysate during the drainage processes in the peritoneal PD of healthy rabbits. The TC catheter had major complications with regard to fluid retention in the abdomen, representing reduced drainage efficiency, while the BL drain showed a greater tendency for the peritoneal fluid to leak.

Для цитирования: Pereira Ana Camila, Geraldes Silvano S, Maia Suellen R, de Azevedo Maria Gabriela P, da Silva Gustavo G, de Souza Bruna N, García Henry David M, Melchert Alessandra, Brandão Cláudia Valéria S, de Souza Fabiana F, Guimarães-Okamoto Priscylla T C. Applicability of the drainage effectiveness of Blake drains and Tenckhoff catheters in the peritoneal dialysis of healthy rabbits (Oryctolagus cuniculus).. Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). 2022. DOI: 10.1111/vec.13252.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.