PURPOSE: We report the case of a thoracic endograft used to achieve exclusion of a ruptured proximal paranastomotic abdominal aortic aneurysm (PAAA) as a consequence of aortic ballooning.

CASE REPORT: A type I proximal endoleak was evidenced following endovascular repair of a PAAA with an aortic cuff. The leak was treated with ballooning, which caused distal aortic rupture. A thoracic endograft was deployed inside the cuff, achieving complete exclusion. At 1 year, there are no signs of migration or endoleak with complete PAAA thrombosis, according to computed tomographic angiography.

CONCLUSION

In hostile proximal abdominal aortic neck, challenging anatomies, or urgent cases, the structural adaptability of thoracic endografts could provide safe and successful abdominal aortic endovascular exclusion.

Для цитирования: Tasselli Sebastiano, Perini Paolo, Paini Elisa, Milan Luca, Bonvini Stefano. Use of a Thoracic Endograft in an Acute Abdominal Aortic Setting: Case Report and Literature Review.. Vascular and endovascular surgery. 2017. DOI: 10.1177/1538574417718446.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.