MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/iembs.2008.4649826

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2008

Normalization and backscatter spectral analysis of human carotid arterial data acquired using a clinical linear array ultrasound imaging system.

Sareen Meghna, Waters Kendall, Nair Anuja, Vince D Geoffrey

СтатьяПеревод пока не подготовлен

Аннотация

The risk of plaque rupture in carotid atherosclerotic disease is associated more closely with the composition of plaque rather than the severity of stenosis. The constituents of plaque can be determined from ultrasonic spectral parameters obtained from normalized backscatter tissue data. Calibration of the data is done using echoes off a specular reflector which removes the system response of an ultrasound transducer, Terason (Teratech Corporation), from the backscatter data. A reference spectrum study is used to compare specular reflectors based on time domain (echo) and frequency domain (power spectrum, centroid and parabola test) analysis. Nylon and a tissue-mimicking phantom (velocity = 1560 m/s, slope of attenuation = 0.7 dB/cm MHz) have an intermediate acoustic impedance with respect to water and appear good choices as specular reflectors for clinical ultrasound imaging scanners compared to Plexiglas and other higher reflecting materials. A tissue-mimicking phantom is used to correct for attenuation in plaque, diffraction and saturation of electronics of the ultrasound scanner. Autoregressive power spectrum estimation methods are used to extract spectral parameters (spectral slope, y-intercept, midband fit, maximum and minimum power with corresponding frequencies, and integrated backscatter) from calibrated tissue data and linear and quadratic discriminant rules developed for classification of carotid arterial plaque. Regions of interest (n = 64; 64 samples x 8 scan lines with 30 MHz sampling frequency) consisting of 48 fibrous-fibrofatty (Class 1), 11 thrombus-necrotic core (Class 2), and 5 dense calcium (Class 3) areas selected for analysis show that fibrosis can be differentiated from necrosis and calcification. The quadratic discriminant rule identified necrosis with a lower misclassification rate (9.1%) than the linear discriminant rule (18.2%).

Для цитирования: Sareen Meghna, Waters Kendall, Nair Anuja, Vince D Geoffrey. Normalization and backscatter spectral analysis of human carotid arterial data acquired using a clinical linear array ultrasound imaging system.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2008. DOI: 10.1109/iembs.2008.4649826.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.