m+Medelevator.RU
← Поиск публикаций
COPD · 2016

Emphysema on Thoracic CT and Exercise Ventilatory Inefficiency in Mild-to-Moderate COPD.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jones Joshua H, Zelt Joel T, Hirai Daniel M, Diniz Camilla V, Zaza Aida, O'Donnell Denis E, Neder J Alberto

Аннотация

There is growing evidence that emphysema on thoracic computed tomography (CT) is associated with poor exercise tolerance in COPD patients with only mild-to-moderate airflow obstruction. We hypothesized that an excessive ventilatory response to exercise (ventilatory inefficiency) would underlie these abnormalities. In a prospective study, 19 patients (FEV1 = 82 ± 13%, 12 Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage 1) and 26 controls underwent an incremental exercise test. Ventilatory inefficiency was assessed by the ventilation ([Formula: see text]E)/CO2 output ([Formula: see text]CO2) nadir. Pulmonary blood flow (PBF) in a submaximal test was calculated by inert gas rebreathing. Emphysema was quantified as % of attenuation areas below 950 HU. Patients typically presented with centrilobular emphysema (76.8 ± 10.1% of total emphysema) in the upper lobes (upper/total lung ratio = 0.82 ± 0.04). They had lower peak oxygen uptake ([Formula: see text]O2), higher [Formula: see text]E/[Formula: see text]CO2 nadir, and greater dyspnea scores than controls (p < 0.05). Lower peak [Formula: see text]O2 and worse dyspnea were found in patients with higher [Formula: see text]E/[Formula: see text]CO2 nadirs (≥30). Patients had blunted increases in PBF from rest to iso-[Formula: see text]O2 exercise (p < 0.05). Higher [Formula: see text]E/[Formula: see text]CO2 nadir in COPD was associated with emphysema severity (r = 0.63) which, in turn, was related to reduced lung diffusing capacity (r = -0.72) and blunted changes in PBF from rest to exercise (r = -0.69) (p < 0.01). Ventilation "wasted" in emphysematous areas is associated with impaired exercise ventilatory efficiency in mild-to-moderate COPD. Exercise ventilatory inefficiency links structure (emphysema) and function (DLCO) to a key clinical outcome (poor exercise tolerance) in COPD patients with only modest spirometric abnormalities.

Предметные рубрики MeSH