MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.atherosclerosis.2007.12.028

Медицинская библиотека · Atherosclerosis · 2008

Carotid artery intima-media thickness correlates with intravascular ultrasound parameters in patients with slow coronary flow.

Camsari Ahmet, Ozcan Turkay, Ozer Caner, Akcay Burak

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Coronary slow flow (CSF) phenomenon is characterized by delayed opacification of coronary vessels in a normal coronary angiogram. Although clinical and pathological features have been previously described, the underlying pathophysiology has not been fully elucidated. We aimed to determine and compare the carotid intima-media thickness (CIMT) values of SCF patients and healthy subjects, and to correlate patients' values with intimal thickness and TIMI frame counts of their coronary arteries (assessed by intravascular ultrasound).

METHODS

The study population consisted of 50 patients with SCF [38(76%) male, aged 53+/-7 years] and 40 normal subjects [22(55%) male, aged 51+/-8 years]. CIMT values, intravascular ultrasonographies and TIMI frame counts of the patients, and CIMT of the controls were investigated.

RESULTS

Upon intravascular ultrasonography investigation, the common finding was longitudinally extended massive calcification throughout the epicardial coronary arteries in 44 (88%) of patients. Mean coronary intimal thickness was 0.52+/-0.1mm. CIMT was significantly increased in SCF patients than controls (0.84+/-0.14 vs. 0.66+/-0.13, p<0.0001). Besides, CIMT was significantly correlated with coronary intima-media thickness. TIMI frame counts were positively correlated with CIMT and coronary intimal thickness (p<0.05 and p<0.05 respectively).

CONCLUSION

These results support the theory that SCF is the result of coronary atherosclerosis which is the part of systemic involvement.

Для цитирования: Camsari Ahmet, Ozcan Turkay, Ozer Caner, Akcay Burak. Carotid artery intima-media thickness correlates with intravascular ultrasound parameters in patients with slow coronary flow.. Atherosclerosis. 2008. DOI: 10.1016/j.atherosclerosis.2007.12.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.