Silent cerebral ischemic lesions after carotid artery stenting with distal cerebral protection.

González Alejandro, Piñero Pilar, Martínez Eva, González-Marcos Jose Ramón, Rafel Enrique, Mayol Antonio, Gil-Peralta Alberto

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate by MR diffusion weighted image (DWI-MR) the presence of new ischemic cerebral lesions after carotid artery stenting (CAS) and distal cerebral protection, in patients with internal carotid artery (ICA) stenosis >70.

METHODS

Sixty-seven CAS were performed under cerebral protection with a distal filter. Mean age of the patients was 68.3 years (range 37-86) and 42 patients (62.7%) were symptomatic. An EZ filter device was used in all cases. The mean length of the procedure was 22.2 minutes (range 8-110). All patients had a cerebral MRI done in the 3 days before CAS and a DW-MR (eco planar single shot, b=1000 mm2/seconds) was done the day after.

RESULTS

As a consequence of the CAS, three transient ischemic attacks were observed. There was one minor stroke (1.5%) on day 21, but no major stroke, death or myocardial infarction in a 30-day period. DW-MRI after CAS showed 26 new silent ischemic lesions in 11 asymptomatic patients (16.4%). In six, they were multiple (range 2-5). Lesions were mainly seen in the ipsilateral medial cerebral artery (21); four in the posterior fossa, and one in the contralateral medial cerebral artery.

DISCUSSION: Although the use of distal cerebral protection was safe, new cerebral ischemic lesions, supposedly embolic, were observed in 16.4% of the patients. Although without clinical consequences in our series, their moderate high incidence should promote the investigation of safer techniques and devices.

Для цитирования: González Alejandro, Piñero Pilar, Martínez Eva, González-Marcos Jose Ramón, Rafel Enrique, Mayol Antonio, Gil-Peralta Alberto. Silent cerebral ischemic lesions after carotid artery stenting with distal cerebral protection.. Neurological research. 2005. DOI: 10.1179/016164105x35431.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.