m+Medelevator.RU
← Поиск публикаций
Archives of orthopaedic and trauma surgery · 2016

Does a positioning rod or a patient-specific guide result in more natural femoral flexion in the concept of kinematically aligned total knee arthroplasty?

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ettinger Max, Calliess Tilman, Howell Stephen M

Аннотация

PURPOSE: Flexion of the femoral component in 5° increments downsizes the femoral component, decreases the proximal reach and surface area of the trochlea, delays the engagement of the patella during flexion, and is associated with a higher risk of patellar-femoral instability after kinematically aligned TKA. The present study evaluated flexion of the femoral component after use of two kinematic alignment instrumentation systems. We determined whether a distal cutting block attached to a positioning rod inserted perpendicular to the distal femoral joint line in the axial plane and 8-10 cm into the distal femur anterior and posterior to the distal cortex of the femur in the sagittal plane or a femoral patient-specific cutting guide sets the femoral component in more natural flexion.

METHODS: Flexion of the femoral component was measured with respect to the sagittal femoral anatomic axis of the distal diaphysis and the sagittal femoral axis on rotationally controlled long-leg lateral computer scanograms. Measurements were performed on 53 consecutive patients treated with a kinematically aligned TKA performed with a distal cutting block attached to a positioning rod, and 53 consecutive patients treated with a kinematically aligned TKA performed with a femoral patient-specific cutting guide.

RESULTS: The average flexion and variability (±standard deviation) of the femoral component of patients treated with a positioning rod was 1° ± 2° and 7° ± 4° with respect to the anatomic and mechanical axes, respectively, which was 5° less than the average flexion of the femoral component of patients treated with a femoral patient-specific cutting guide of 6° ± 4° and 12° ± 5° (p = 0.0001, p = 0.0001, respectively).

CONCLUSIONS: Because a distal cutting block attached to a positioning rod sets the femoral component in 5° less flexion and with less variability than a femoral patient-specific cutting guide, we prefer this instrumentation system when performing kinematically aligned TKA to reduce the risk of patellar-femoral instability. Each surgeon should determine the repeatability of setting the flexion of the femoral component with this instrumentation system.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты