MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0000000000000692

Медицинская библиотека · Journal of orthopaedic trauma · 2016

Current Evidence: Plate Versus Intramedullary Nail for Fixation of Distal Tibia Fractures in 2016.

Vallier Heather A

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Displaced distal tibia shaft fractures are effectively treated with standard plates and intramedullary nails. Plate fixation performed with meticulous soft tissue handling results in minimal risks of infection and poor wound healing. Standard plates have high rates of primary union, whereas locking plates may delay union because of increased stiffness. Tibial healing may also be delayed after plating of the fibula, although fibula reduction and fixation may aid accuracy of reduction of the tibia. Malalignment occurs more often with infrapatellar intramedullary nailing versus plates, and early results of suprapatellar nailing appear promising in minimizing intraoperative malalignment. Long-term function after fixation of the distal tibia is good for most, with poor outcomes often associated with baseline social and mental health issues.

Для цитирования: Vallier Heather A. Current Evidence: Plate Versus Intramedullary Nail for Fixation of Distal Tibia Fractures in 2016.. Journal of orthopaedic trauma. 2016. DOI: 10.1097/bot.0000000000000692.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.