MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ehf2.12367

Медицинская библиотека · ESC heart failure · 2018

Rationale and design of the EU-CERT-ICD prospective study: comparative effectiveness of prophylactic ICD implantation.

Zabel Markus, Sticherling Christian, Willems Rik, Lubinski Andrzej, Bauer Axel, Bergau Leonard, Braunschweig Frieder, Brugada Josep, Brusich Sandro, Conen David, Cygankiewicz Iwona, Flevari Panagiota, Taborsky Milos, Hansen Jim, Hasenfuß Gerd, Hatala Robert, Huikuri Heikki V, Iovev Svetoslav, Kääb Stefan, Kaliska Gabriela, Kasprzak Jaroslaw D, Lüthje Lars, Malik Marek, Novotny Tomas, Pavlović Nikola, Schmidt Georg, Shalganov Tchavdar, Sritharan Rajeeva, Schlögl Simon, Szavits Nossan Janko, Traykov Vassil, Tuinenburg Anton E, Velchev Vasil, Vos Marc A, Willich Stefan N, Friede Tim, Svendsen Jesper Hastrup, Merkely Béla, EU-CERT-ICD Study Investigators

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value.

METHODS AND

RESULTS

The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non-randomized control group). The primary endpoint is all-cause mortality; the co-primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost-effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12-lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years.

CONCLUSIONS

The EU-CERT-ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers.

Для цитирования: Zabel Markus, Sticherling Christian, Willems Rik, Lubinski Andrzej, Bauer Axel, Bergau Leonard, Braunschweig Frieder, Brugada Josep, Brusich Sandro, Conen David, Cygankiewicz Iwona, Flevari Panagiota, Taborsky Milos, Hansen Jim, Hasenfuß Gerd, Hatala Robert, Huikuri Heikki V, Iovev Svetoslav, Kääb Stefan, Kaliska Gabriela, Kasprzak Jaroslaw D, Lüthje Lars, Malik Marek, Novotny Tomas, Pavlović Nikola, Schmidt Georg, Shalganov Tchavdar, Sritharan Rajeeva, Schlögl Simon, Szavits Nossan Janko, Traykov Vassil, Tuinenburg Anton E, Velchev Vasil, Vos Marc A, Willich Stefan N, Friede Tim, Svendsen Jesper Hastrup, Merkely Béla, EU-CERT-ICD Study Investigators. Rationale and design of the EU-CERT-ICD prospective study: comparative effectiveness of prophylactic ICD implantation.. ESC heart failure. 2018. DOI: 10.1002/ehf2.12367.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.