Journal of orthodontics · 2023

Finite element analysis of two skeletally anchored maxillary molar distalisation methods.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vilanova Lorena, Bellini-Pereira Silvio Augusto, Patel Mayara Paim, Grec Roberto, Henriques José Fernando Castanha, Janson Guilherme, Garib Daniela, Aliaga-Del Castillo Aron

Аннотация

OBJECTIVE: To compare two methods of maxillary molar distalisation with skeletal anchorage using finite element analysis (FEA).

METHODS: Two digitised models were created: the miniscrew-anchored distaliser, which consisted of a distalisation method anchored in a buccal miniscrew between the first molar and second premolar (Model 1), and the miniscrew-anchored palatal appliance, which consisted of a distalisation method anchored in a miniscrew on the anterior region of the palate (Model 2). FEA was used to simulate both methods, assessing teeth displacements and stress concentration.

RESULTS: The miniscrew-anchored distaliser showed greater buccal than distal displacement of the first molar, while the opposite was observed in the miniscrew-anchored palatal appliance. The second molar responded similarly in the transverse and anteroposterior perspectives with both appliances. Greater displacements were observed at crown level than in apical regions. Greater stress concentration was observed at the buccal and cervical regions of the crown in the miniscrew-anchored distaliser and the palatal and cervical regions in the palatal appliance. The stress progressively spread in the buccal side of the alveolar bone for the miniscrew-anchored distaliser and in the palatal root and alveolar bone for the palatal appliance.

CONCLUSION: FEA assumes that both appliances would promote maxillary molar distalisation. A skeletally anchored palatal distalisation force seems to provide a greater molar bodily movement with less undesirable effects. Greater stress is expected at the crown and cervical regions during distalisation, and the stress concentration in the roots and alveolar bone depends directly on the region the force was applied.