MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40510-023-00455-6

Медицинская библиотека · Progress in orthodontics · 2023

Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study.

Somaskandhan Abinaya, Kumar N M Vijay, Vijayalakshmi R Devaki

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To three-dimensionally analyse the stress distribution and displacement pattern in the maxillofacial complex following intrusion and distalization of the maxillary arch using finite element analysis in skeletal class II malocclusion with prognathic maxilla and vertical maxillary excess using miniplates and mini-implants.

MATERIALS AND

METHODS

Finite Element models of a skull, Y-shaped stainless steel miniplate, mini-implant and a posted arch were generated. Three force levels (1) 200 g (2) 300 g and (3) 500 g per side were applied to the assembly. The models were pre-processed and the analysis was performed using ANSYS version 18.1 software. Alterations in von mises stress, principal maximum stress, principal minimum stress and compressive stress were analysed around the sutures and surface landmarks.

RESULTS

With miniplates, there was a maximum stress concentration at the zygomatic buttress with even stress distribution at the fronto-maxillary, zygomatico-temporal, zygomatico-frontal and pterygomaxillary sutures along with anatomical landmarks such as frontal process of maxilla, ANS, Point A, prosthion and maxillary process of zygoma. First molars experienced greater distalization effects with buccal flaring when miniplates were used. With mini-implants, canine and premolars also exhibited greater distalization effects. In the root apices, lateral incisors showed increased lingual root movement with mini-implants.

CONCLUSION

Miniplates provide a greater distalizing effect while mini-implants produce increased intrusive effect. The distalizing effect is greater when 500 g of force is applied using miniplates with significantly even stress distribution and displacement pattern.

Для цитирования: Somaskandhan Abinaya, Kumar N M Vijay, Vijayalakshmi R Devaki. Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study.. Progress in orthodontics. 2023. DOI: 10.1186/s40510-023-00455-6.

Предметные рубрики MeSH

Подготовка и перевод публикации