DOI 10.2147/copd.s596874

Медицинская библиотека · International journal of chronic obstructive pulmonary disease · 2026

Laryngeal Responses During Non-Invasive Ventilation in Stable Chronic Obstructive Pulmonary Disease: An Observational Study.

Brekka Anne Kristine, Solli Petrine Veierød, Indrekvam Solfrid, Engeset Merete Salveson, Røksund Ola Drange, Lehmann Sverre, Clemm Hege Havstad, Halvorsen Thomas, Heimdal John-Helge, Murphy Patrick Brian, Vollsæter Maria, Andersen Tiina Maarit

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Long-term non-invasive ventilation (NIV) is an established therapy for hypercapnic chronic obstructive pulmonary disease (COPD); however, many patients remain challenging to ventilate effectively. We hypothesized that NIV-induced laryngeal obstruction (NIV-ILO), observed during laryngoscopy, may contribute to reduced ventilatory effectiveness, and that this obstruction can be identified using laryngeal ultrasound (US).

PATIENTS AND

METHODS

This exploratory cross-sectional study included 15 participants with stable COPD receiving long-term NIV. Laryngeal responses were assessed using transnasal flexible laryngoscopy (TFL) and US. Assessments began during spontaneous breathing, followed by NIV at each participant's prescribed settings. Inspiratory positive airway pressure (IPAP) was increased in 2 cmH2O increments to the device's maximum. Laryngeal responses were assessed in real time and reassessed retrospectively from video recordings. The participants rated discomfort using a numeric rating scale (0-10).

RESULTS

Fifteen participants (40% female) were included. The prescribed IPAP ranged from 7 to 30 cmH2O, with NIV-ILO observed in 5 of 15 participants at a median of 22.0 cmH2O. During subsequent pressure increments, additional 6 of 15 developed NIV-ILO at a median (range) IPAP of 20.5 cmH2O (16.0-30.0), yielding 11 participants (73.3%) developing NIV-ILO within the pressure range of their device. US was assessable in 11 participants, with the structures of interest visualized during 54 of 63 pressure increments. The two methods demonstrated complete concordance for all assessable findings.

CONCLUSION

NIV-ILO was common in patients with COPD using long-term NIV, occurring within the pressure range typically applied to achieve effective ventilation. US can serve as a less invasive diagnostic alternative to TFL.

Для цитирования: Brekka Anne Kristine, Solli Petrine Veierød, Indrekvam Solfrid, Engeset Merete Salveson, Røksund Ola Drange, Lehmann Sverre, Clemm Hege Havstad, Halvorsen Thomas, Heimdal John-Helge, Murphy Patrick Brian, Vollsæter Maria, Andersen Tiina Maarit. Laryngeal Responses During Non-Invasive Ventilation in Stable Chronic Obstructive Pulmonary Disease: An Observational Study.. International journal of chronic obstructive pulmonary disease. 2026. DOI: 10.2147/copd.s596874.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.