MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm12237330

Медицинская библиотека · Journal of clinical medicine · 2023

How Refined Surgical Technical Solutions Can Make Bentall Operation a Low-Risk Procedure: 20-Year Personal Experience at the "Root" of the Aortic Diseases-It Is Time to Change Surgical Guidelines.

Ruvolo Giovanni, Altieri Claudia, Bassano Carlo, Buioni Dario, Nardi Paolo, Pisano Calogera

СтатьяПеревод пока не подготовлен

Аннотация

(1)

Objective

Twenty years' experience of Bentall-De Bono operations by one surgeon. (2)

Methods

From January 2003 to September 2023, four-hundred-and-two patients aged 65.9 ± 15 years underwent a Bentall operation. The EuroScore-2 was 5.0% ± 3.8%. Associated procedures were performed on 113 patients (28.1%).

Results

Operative mortality was 1.2% (n = 5), in particular 0.69% (n = 2/289) for isolated Bentall operation, 2.65% (n = 3/113) for combined procedures (p < 0.05). Postoperative acute heart failure occurred in 38 patients (9.45%). Preoperative pulmonary hypertension (44 ± 14 vs. 33 ± 7 mmHg), cardiopulmonary bypass time (169 ± 61 min. vs. 124 ± 42 min.) and aortic cross-clamp time (133 ± 45 min. vs. 107 ± 34 min.) have been recognized as independent predictors of mortality and cardiac complications (p < 0.05).

Conclusions

In our experience, the Bentall operation was associated with low operative mortality and low rate of complications. For this reason, in agreement with the patients, we have modified surgical indication for ascending aortic aneurysms and now we think that it is time to change surgical guidelines.

Для цитирования: Ruvolo Giovanni, Altieri Claudia, Bassano Carlo, Buioni Dario, Nardi Paolo, Pisano Calogera. How Refined Surgical Technical Solutions Can Make Bentall Operation a Low-Risk Procedure: 20-Year Personal Experience at the "Root" of the Aortic Diseases-It Is Time to Change Surgical Guidelines.. Journal of clinical medicine. 2023. DOI: 10.3390/jcm12237330.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.