Improvement in imaging common temporal bone pathologies at 3 T MRI: small structures benefit from a small field of view.

Schulze M, Reimann K, Seeger A, Klose U, Ernemann U, Hauser T K

СтатьяПеревод в очереди

Аннотация

AIM: To compare image quality and evaluate its clinical importance in common temporal bone pathologies of a pTX-SPACE (parallel transmit [pTX] three-dimensional turbo spin-echo with variable flip angle [SPACE]) magnetic resonance imaging (MRI) sequence improved for spatial resolution to a standard-SPACE sequence exhibiting the same scan time at 3 T.

MATERIALS AND

METHODS

Thirty-four patients were examined using a standard-SPACE and resolution improved pTX-SPACE sequence at 3 T MRI. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and image quality were assessed. Diseases investigated were vestibular schwannoma (VS), intralabyrinthine schwannoma (ILS), inner ear malformations, labyrinthitis, temporal bone fractures, and situation after VS resection.

RESULTS

Edge definition, intratumoural pattern, discrimination of VS from the modiolus and edge definition of ILS, separability from the spiral lamina, and detectability within cochlear turns were improved on the pTX-SPACE sequence. Detectability of malformations, post-traumatic changes, and discrimination of the cochlear and facial nerve after VS resection was improved on the pTX-SPACE sequence. In labyrinthitis, pTX-SPACE was not superior to standard-SPACE. The SNR and CNR were significantly reduced for pTX-SPACE.

CONCLUSIONS

pTX-SPACE significantly improves the detectability of temporal bone diseases, in particular, VS, ILS, and post-VS resection.

Для цитирования: Schulze M, Reimann K, Seeger A, Klose U, Ernemann U, Hauser T K. Improvement in imaging common temporal bone pathologies at 3 T MRI: small structures benefit from a small field of view.. Clinical radiology. 2016. DOI: 10.1016/j.crad.2016.11.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.